DINO 180T-1
75
LIMIT SWITCHES
RK3:
:
PREVENTS THE OUTRIGGER FUNCTIONS WHEN THE BOOM IS NOT SET DOWN
ONTO THE SUPPORT (IN TRANSPORT POSITION) AS WELL AS DRIVING DEVICE
FUNCTIONING (CONTROLS RELAY RL30)
RK4:
SAFETY LIMIT SWITCH FOR THE REACH AREA.
RK5:
BACKUP LIMIT SWITCH FOR RK4 SAFETY LIMIT SWITCH.
WHEN ACTIVATED IMMEDIATELY CONTROLS THE SIGNAL HORN ÄM2 AND RL25 AFTER
A SET DELAY (5 SEC.)
RL25 RESETS WHEN THE OVERLOAD SITUATION IS ENDED.
RK7:
BOOM TELESCOPIC CHAIN SYSTEM SAFETY LIMIT SWITCH.
WHEN ACTUATED THE POWER UNIT IS STOPPED (BREAKS THE MINUS POLE OF THE
SPOOL K1) AND BOOM MOVEMENTS ARE PREVENTED.
EMERGENCY DESCENT AND TELESCOPE RETRACTION STAY FUNCTIONAL, AFTER
RETRACTION BOOM LOWERING IS FUNCTIONAL.
RK8:
IF THERE IS A FAULT SITUATION IN RK4 THE BOOM CANNOT BE LOWERED
BEFORE THE TELESCOPE IS FULLY RETRACTED
(RK8 POINTS CLOSE).
RK9:
INDUCTIVE LIMIT SWITCH
LIMITS THE PLATFORM LEFT TURN MOVEMENT
RK10:
INDUCTIVE LIMIT SWITCH
LIMITS THE PLATFORM RIGHT TURN MOVEMENT
OUTRIGGER SAFETY LIMIT SWITCHES (
RK11
,
RK12
,
RK13
AND
RK14
) PREVENTS BOOM
FUNCTIONS IF THERE IS A LOAD ON THE TYRES.
Содержание DINO 180 T
Страница 2: ...DINO 180T 1 2 ...
Страница 3: ...DINO 180T 1 3 OPERATION INSTRUCTIONS Valid from serial number 4505 ...
Страница 6: ...DINO 180T 1 6 REACH DIAGRAM ...
Страница 36: ...DINO 180T 1 36 LUBRICATION PLAN 15 7 ...
Страница 38: ...DINO 180T 1 38 1 ...
Страница 51: ...DINO 180T 1 51 Notes ...
Страница 71: ...DINO 180T 1 71 Notes ...
Страница 79: ...DINO 180T 1 79 ELECTRIC SCHEMA 4433 ...
Страница 80: ...DINO 180T 1 80 ...
Страница 81: ...DINO 180T 1 81 ...
Страница 82: ...DINO 180T 1 82 ...
Страница 83: ...DINO 180T 1 83 ...
Страница 84: ...DINO 180T 1 84 ...
Страница 85: ...DINO 180T 1 85 ...
Страница 86: ...DINO 180T 1 86 ...
Страница 87: ...DINO 180T 1 87 ...
Страница 88: ...DINO 180T 1 88 ...
Страница 89: ...DINO 180T 1 89 Notes ...
Страница 91: ...DINO 180T 1 91 HYDRAULIC SCHEME 4371 4375 4387 ...
Страница 92: ...DINO 180T 1 92 Notes ...