DINO 180T-1
66
CAUSE REMEDY
8. The boom cannot be raised
- refer to item 4
- the solenioid valve is open
- other causes, ref. solenoid valve sticking
- Turning function activated when using raise
control
- turning solenoid valve stuck in position
"turning"
- clean spindle and housing thoroughly
9. Telescope does not work
- Refer to item 4
- Check that telescope solenoid valve is not in
central (open) position
10. Telescope retracts slowly
- load regulating valve leaks
- as in item 5 (hold valve)
11. Platform moves rearwards
- platform floor load regulating (two-way) valve
leaks
- as in item 5 (hold valve)
- load regulating valve below platform leaks
- as in item 5 (hold valve)
Содержание DINO 180 T
Страница 2: ...DINO 180T 1 2 ...
Страница 3: ...DINO 180T 1 3 OPERATION INSTRUCTIONS Valid from serial number 4505 ...
Страница 6: ...DINO 180T 1 6 REACH DIAGRAM ...
Страница 36: ...DINO 180T 1 36 LUBRICATION PLAN 15 7 ...
Страница 38: ...DINO 180T 1 38 1 ...
Страница 51: ...DINO 180T 1 51 Notes ...
Страница 71: ...DINO 180T 1 71 Notes ...
Страница 79: ...DINO 180T 1 79 ELECTRIC SCHEMA 4433 ...
Страница 80: ...DINO 180T 1 80 ...
Страница 81: ...DINO 180T 1 81 ...
Страница 82: ...DINO 180T 1 82 ...
Страница 83: ...DINO 180T 1 83 ...
Страница 84: ...DINO 180T 1 84 ...
Страница 85: ...DINO 180T 1 85 ...
Страница 86: ...DINO 180T 1 86 ...
Страница 87: ...DINO 180T 1 87 ...
Страница 88: ...DINO 180T 1 88 ...
Страница 89: ...DINO 180T 1 89 Notes ...
Страница 91: ...DINO 180T 1 91 HYDRAULIC SCHEME 4371 4375 4387 ...
Страница 92: ...DINO 180T 1 92 Notes ...