
DINO 125T
61
- Disable RK4 by disconnecting lead 40 and using a jumper lead to connect leads 33
and 39 together (lower operating panel) for the duration of the test.
- Retract the boom and extend it again, measuring the extending part of the telescope
- The length should be 3600 ± 30 mm (141,7 ± 1,2 inches)
- If the extending part is too long, adjust the limit switches and secure them by
applying a seal.
- Retract the boom and reset the relay R25 from the button (fig.3)
-
WARNING!
Do not forget to make the limit switch RK4 functional by reconnecting
lead 40 to the terminal block.
Setting the overload devices Rk4 and Rk5 (fig. 2, 4)
When servicing, always test both overload limit switches
- Load the platform with for example 80 kg (175 lbs)
- Move the boom into horizontal position
Setting procedure, alternative 1.
- Set the actuating point of RK4 far enough to ensure that RK5 is actuated before RK4
- Extend the boom, and measure one part of it (stroke)
- The stroke should be 3600 ± 30 mm (141,7 ± 1,2 inches)
- Tighten the adjustment locking nut and test the actual values once more (if Rk5 is actuated for
more than 4 seconds, relay R25 must be reset)
- RK4 should be set to actuate before RK5
- Extend the boom and measure the stroke
- The length should be 2900 + 30 mm (114 ± 1,2 inches)
- Tighten the adjusting screw and test the actual values once more
- Attach a securing wire onto the adjusting screw in a way that excludes every possibility to unscrew
the adjusting screw, and attach a seal to the wire
- Fasten the protective panel
Elsewhere in this manual another alternative way of securing the RK5 is described, for the
case that the securing wire is already attached (regular service, item 10)
Содержание DINO 125T
Страница 2: ...DINO 125T 2...
Страница 3: ...DINO 125T 3 OPERATION INSTRUCTIONS Valid from serial number 12134...
Страница 6: ...DINO 125T 6 REACH DIAGRAM...
Страница 13: ...DINO 125T 13 Fig 1 Fig 4 Fig 2 Fig 5 Fig 3...
Страница 15: ...DINO 125T 15...
Страница 18: ...DINO 125T 18...
Страница 19: ...DINO 125T 19 Notes...
Страница 20: ...DINO 125T 20 Fig 2 Fig 4 Fig 1 Fig 3...
Страница 22: ...DINO 125T 22 Fig 2 Fig 4 Fig 1 Fig 3...
Страница 24: ...DINO 125T 24...
Страница 26: ...DINO 125T 26...
Страница 28: ...DINO 125T 28...
Страница 30: ...DINO 125T 30...
Страница 32: ...DINO 125T 32...
Страница 34: ...DINO 125T 34...
Страница 36: ...DINO 125T 36...
Страница 41: ...DINO 125T 41 340 mm...
Страница 43: ...DINO 125T 43 LUBRICATION PLAN...
Страница 45: ...DINO 125T 45 Fig 1 Fig 2 Fig 3...
Страница 49: ...DINO 125T 49...
Страница 50: ...DINO 125T 50 MUISTA PUHTAUS KOM IH G RENHET VERGESSEN NICHT REINHEIT REMEMBER CLEANLINESS...
Страница 52: ...DINO 125T 52 MUISTA PUHTAUS KOM IH G RENHET VERGESSEN NICHT REINHEIT REMEMBER CLEANLINESS...
Страница 54: ...DINO 125T 54 Fig 2 Fig 3 Fig 5 Fig 4 Fig 1...
Страница 56: ...DINO 125T 56 Fig 2 Fig 3 Fig 5 Fig 4 Fig 1...
Страница 58: ...DINO 125T 58 Fig 1 Fig 3 Fig 4 Fig 2...
Страница 60: ...DINO 125T 60 Fig 1 Fig 2 Fig 3 Fig 4...
Страница 62: ...DINO 125T 62 Fig 1 Fig 2...
Страница 64: ...DINO 125T 64...
Страница 76: ...DINO 125T 76 Muistiinpanoja Annotations Notes Notizen...
Страница 78: ...DINO 125T 78 Fig 2 Fig 1...
Страница 80: ...DINO 125T 80 Fig 1 Fig 2...
Страница 82: ...DINO 125T 82...
Страница 84: ...DINO 125T 84 Fig 2 Fig 1...
Страница 87: ...DINO 125T 87 ELECTRIC SCHEME PLATFORM TURNING 12114...
Страница 88: ...DINO 125T 88 ELECTRIC SCHEME 230VAC 12001...
Страница 89: ...DINO 125T 89 ELECTRIC SCHEME 230VAC Lifts with no electric motor M1 12134 12141...
Страница 90: ...DINO 125T 90 ELECTRIC SCHEME 12VDC 12054...
Страница 91: ...DINO 125T 91 ELECTRIC SCHEME 12VDC Lifts with no electric motor M1 12134 12141...
Страница 93: ...DINO 125T 93 HYDRAULIC SCHEME 12034...
Страница 94: ...DINO 125T 94 Notes...