Power off alarm status symbol included in power in the location information. According to the
time interval upload it.

5, Custom alarm (high and low sensor alarm)

This type of terminal support 1 road low and 1 road high sensor

Sensor alarm status signs included in the location information. According to the time interval
upload it.

6, Robbery/SOS alarm

Rob/SOS alarm sign a included in the position in the information. When you press the alarm
button above 0.5 seconds, such as in robbery/SOS alarm conditions ,it would alarm.If you
under the alarm condition,it would cancel the alarm. When it alarms,the button’s light stays
on,when cancel the alarm,the button’s light off.
Alarm way: When the fist alarm,it would upload a message. It is according to time interval to
upload the message.

Cancel alarm way: The monitoring center send the calcelling alarm instructions.

7, Geo- fence alarm

After you set up the Geo-fence,when you run in and out of the fence,the terminal would
upload a hint information.

Alarm way: Triggered alarm.

Other

1 Mileage statistics

The in all moving position of GPS, the unit is m

The maximum is 16777215 meters. When it achieve to maximum value,it would re-caculate
the statistics from 0.

Statistical conditions: The vehicles power on and the GPS effective positioning.

2 Blind area

When the vehicles in GPRS signal blind area, the terminal will automatically save the
location data according to schedule resending time (When the car power on), after the
vehicles received the GPRS signal, the terminal would automatically send the saved datas
that in blind area to the monitoring center,it can save 1500 datas at most.

Содержание A300

Страница 1: ...o Ltd Tel 86 10 52679667 57430056 http www dingtek com E mail gps dingtek com Room 605 Building Botai B Nanhudongyuan 122 Chaoyang District Beijing China 100102 Page 1 GPS Vehicle Tracker A300 User manual Version V1 3 Date 2012 09 05 ...

Страница 2: ...d Tel 86 10 52679667 57430056 http www dingtek com E mail gps dingtek com Room 605 Building Botai B Nanhudongyuan 122 Chaoyang District Beijing China 100102 Page 2 Index Query function 3 Settings 3 Control 5 Alarm 6 Other 7 wire diagram 8 ...

Страница 3: ...on software release time Settings 1 Fixed time set times to return position information settings Set designated vehicles according to the fixed time times to send the location information to the center through UDP This instruction request the terminal use interval as the time interval return location information up to 65535 times positioning information 2 Fixed time return location information s t...

Страница 4: ...d restrict the vehicles only can drive in the permitted line range At present it only support 1 line node 6 IP and port setting The monitoring center can change the terminal IP number and port number at any time After you change the terminal the new IP and port number would take effect immediately After you changed the IP port the terminal would reply response information to the original IP port a...

Страница 5: ...minal and testing the terminal s working state the terminal increase the short message debugging instructions When you using text messages to read parameters you don t need not to input password but if you want to change the machine parameters you have to input the correct password Control 1 Remote restart When the monitoring center remote send the restart instructions the terminal will automatica...

Страница 6: ...ld upload a message The rest alarm would according to the scheduled time resending time s interval to upload the message Cancel alarm way You should send the cancelling alarm instructions to the terminal and the vehicles running speed is smaller than overspeed alarm witnesses value Send the cancelling overspeed instructions and close the overspeed alarm 2 Parking overtime alarm valve setting After...

Страница 7: ...ht stays on when cancel the alarm the button s light off Alarm way When the fist alarm it would upload a message It is according to time interval to upload the message Cancel alarm way The monitoring center send the calcelling alarm instructions 7 Geo fence alarm After you set up the Geo fence when you run in and out of the fence the terminal would upload a hint information Alarm way Triggered ala...

Страница 8: ...eijing China 100102 Page 8 5 SMS or platform remote inquires the terminal parameters You can check the terminal s parameter configuration through SMS or GPRS instruciton These parameter configurations include parameters of the terminal such as TCP UDP the terminal code resending time APN Error record etc wire diagram Main Main Main Main I O I O I O I O port port port port ...

Страница 9: ...n 7 Orange SoS button Pin 8 Purple Oil cut Pin 9 10 Reserved RS232 RS232 RS232 RS232 port port port port Pin 1 RX 232 Pin 2 TX 232 Pin 3 GND Pin 4 5V output Connected with Z100 cement drum sensor Tracker RS232 Pin 3 GND Z100 Blue line GND Tracker RS232 Pin 4 5V output Z100 Brown line VCC Tracker IO port Pin 4 Brown Green Z100 Black line Connect with Temperature Box Tracker RS232 pin x Temperature ...

Страница 10: ... Solution check whether GPS antenna covered by some metal objects whether the copper coil of the port break off 3 GPS module broken the lights keeps lighting off Reasons The lights tube broken GPS module broken suggest return the terminal to factory for repairing GSM light red 1 GPRS connect to the center successfully 0 5 seconds light on off light flashing quickly 2 SIM card register GPRS failed ...

Отзывы: