Note: When the car power on, the time interval of the return location information’s minimum
unit is 3 seconds.

3, Over-speed alarm threshold settings

After you set up the over-speed alarm’s threshold, if the vehicles’ speed is > the threshold
valve, and the time would stays for 10 seconds, it will alarm.

The factory default for closed terminals (i.e. set value 0)

Set the value is more than 10 km/h is valid.

4, Parking overtime alarm valve setting

After set up the parking overtime alarm valve, when the car’s speed is 0,and the time stays
or greater than the overtime alarm valve, it would alarm. When you set up the overtime alarm
valve, you must set the valve more than 1 seconds is valid.

The factory default for closed terminals (i.e. set value 0)

5, Electronic fence Settings

Terminal support maximum 50 electronic fence with a range of rectangular fence, When you
drive in and out of the fence, the terminal will upload a hint.

When the terminal issued the line node to the appointed vehicles, it would restrict the
vehicles only can drive in the permitted line range. At present, it only support 1 line node.
6, IP and port setting

The monitoring center can change the terminal IP number and port number at any time. After
you change the terminal, the new IP and port number would take effect immediately.

After you changed the IP port, the terminal would reply response information to the original
IP port, and rebuild connection request to the new IP port at the same time. When the
terminal send the TCP connection to the monitoring center, it would discard(not close) the
original connection, the connection of monitoring center is still exist. So the monitoring center
GPRS server also need to check whether there is repeatedly connecting, if there is
repeatedly connecting, you need to clear the terminal’s original connecting, otherwise the
GPS server can’t bear it because of opening too much linkage.

8, TCP heartbeat interval setting

When you set designated vehicles according to set time upload the location information, this
position information would use TCP to upload the information, this instruction main as TCP
heartbeat instructions

Host default for 3 minutes. This parameter would not lost when the power off.

After the establishment of the TCP connection by mobile router keep period of time, if the
TCP transmission interval is too long, the terminal would not reserve the connection, the

Содержание A300

Страница 1: ...o Ltd Tel 86 10 52679667 57430056 http www dingtek com E mail gps dingtek com Room 605 Building Botai B Nanhudongyuan 122 Chaoyang District Beijing China 100102 Page 1 GPS Vehicle Tracker A300 User manual Version V1 3 Date 2012 09 05 ...

Страница 2: ...d Tel 86 10 52679667 57430056 http www dingtek com E mail gps dingtek com Room 605 Building Botai B Nanhudongyuan 122 Chaoyang District Beijing China 100102 Page 2 Index Query function 3 Settings 3 Control 5 Alarm 6 Other 7 wire diagram 8 ...

Страница 3: ...on software release time Settings 1 Fixed time set times to return position information settings Set designated vehicles according to the fixed time times to send the location information to the center through UDP This instruction request the terminal use interval as the time interval return location information up to 65535 times positioning information 2 Fixed time return location information s t...

Страница 4: ...d restrict the vehicles only can drive in the permitted line range At present it only support 1 line node 6 IP and port setting The monitoring center can change the terminal IP number and port number at any time After you change the terminal the new IP and port number would take effect immediately After you changed the IP port the terminal would reply response information to the original IP port a...

Страница 5: ...minal and testing the terminal s working state the terminal increase the short message debugging instructions When you using text messages to read parameters you don t need not to input password but if you want to change the machine parameters you have to input the correct password Control 1 Remote restart When the monitoring center remote send the restart instructions the terminal will automatica...

Страница 6: ...ld upload a message The rest alarm would according to the scheduled time resending time s interval to upload the message Cancel alarm way You should send the cancelling alarm instructions to the terminal and the vehicles running speed is smaller than overspeed alarm witnesses value Send the cancelling overspeed instructions and close the overspeed alarm 2 Parking overtime alarm valve setting After...

Страница 7: ...ht stays on when cancel the alarm the button s light off Alarm way When the fist alarm it would upload a message It is according to time interval to upload the message Cancel alarm way The monitoring center send the calcelling alarm instructions 7 Geo fence alarm After you set up the Geo fence when you run in and out of the fence the terminal would upload a hint information Alarm way Triggered ala...

Страница 8: ...eijing China 100102 Page 8 5 SMS or platform remote inquires the terminal parameters You can check the terminal s parameter configuration through SMS or GPRS instruciton These parameter configurations include parameters of the terminal such as TCP UDP the terminal code resending time APN Error record etc wire diagram Main Main Main Main I O I O I O I O port port port port ...

Страница 9: ...n 7 Orange SoS button Pin 8 Purple Oil cut Pin 9 10 Reserved RS232 RS232 RS232 RS232 port port port port Pin 1 RX 232 Pin 2 TX 232 Pin 3 GND Pin 4 5V output Connected with Z100 cement drum sensor Tracker RS232 Pin 3 GND Z100 Blue line GND Tracker RS232 Pin 4 5V output Z100 Brown line VCC Tracker IO port Pin 4 Brown Green Z100 Black line Connect with Temperature Box Tracker RS232 pin x Temperature ...

Страница 10: ... Solution check whether GPS antenna covered by some metal objects whether the copper coil of the port break off 3 GPS module broken the lights keeps lighting off Reasons The lights tube broken GPS module broken suggest return the terminal to factory for repairing GSM light red 1 GPRS connect to the center successfully 0 5 seconds light on off light flashing quickly 2 SIM card register GPRS failed ...

Отзывы: