Rev 1.3 22.07.09
Dingo Reference Manual
16
These records are available for the past 99 days
on the screen of the controller. The controller
actually keeps records for over one year, but for
practical reasons, these can only be accessed via
the computer interface. The records are not lost
if the power is disconnected.
At the start of each day record is the DAY
screen. This shows which day’s data you are
looking at (DAY 1 = yesterday, DAY 2 = the day
before yesterday, etc.)
For help with navigating through the History,
refer to Fig.6B.
A long push on each of the screens except EXIT
will move down to the next day or the next day’s
value. Short pushes move between figures for
the same day.
NEXT goes to the next day, BACK goes to the
previous day. The day numbers wrap around
when they reach the end.
A short push on the EXIT screen will take you
back to the beginning of that day’s record. A long
push will exit back to the DATA screen.
6
Thin arrow = short push
Thick arrow = long push
BATV
CHRG
LOAD
IN
OUT
DATA
SET
DAY 1 IN OUT VMAX VMIN FTIM SOC NEXT BACK EXIT
DAY 2 DAY 99 DATA
VMAX VMIN FTIM SOC TEMP SOLV
HIST
DAY 2 IN OUT VMAX VMIN FTIM SOC NEXT BACK EXIT
DAY 3 DAY 1 DATA
DAY 3 IN OUT VMAX VMIN FTIM SOC NEXT BACK EXIT
DAY 4 DAY 2 DATA
DAY 99 IN OUT VMAX VMIN FTIM SOC NEXT BACK EXIT
...
...
...
...
...
...
...
DAY 1 DAY 98 DATA
Long push
to adjust
Toggle setting lockout
(’A’ showing means
settings adjustable)
Fig. 6B - The History Menu