 ANNEX: 12.7 WARRANTY CERTIFICATE/CUSTOMER SERVICE

Warranty certificate (valid in Germany)

The  following  conditions,  which  describe  the  terms  and

conditions of our warranty, do not affect the obligations of

the vendor to honor the warranty as specified in the sales

contract with the end user. For the units, we offer warranty

in  accordance  with  the  conditions  below:
We remedy defects to the unit which are demonstrated to

be  the  result  of  material  or  manufacturing  faults  when  we

are notified of these immediately following the discovery of

such defects and within 24 months following delivery to the

end user free of charge, subject to the following proviso. In

the event that the defect becomes apparent within 6 months

following  delivery  and  commissioning  (heating  heat  pump

and  central  apartment  ventilating  systems)  has  been

successfully  performed  by  the  authorized  system

engineering customer service, it can be assumed that the

cause is a material or manufacturing fault.
The  warranty  conditions  apply  to  this  unit  only  when  it  is

purchased by a contractor in one of the member countries

of the European Union, is operated in Germany during the

time  at  which  the  defect  occurs,  and  warranty  services

can be performed in Germany.
The  elimination  of  the  defects  which  we  recognize  as

legitimate  claims  against  warranty  encompasses,  subject

to our choice, the  repair or replacement by flawless parts

of  the  defective  parts.  We  cannot  assume  extraordinary

repair  costs  arising  from  the  type  or  location  or  poor

accessibility  of  the  unit.  Removed  parts  which  we  take

back  become  our  property.  The  warranty  period  for  the

rectification  of  defects  and  replacement  parts  ends  with

the elapsing of the original warranty period for the unit. The

warranty does not extend to fragile  parts which only impair

the  value  or  the  usefulness  of  the  unit  insignificantly. The

original  proof  of  purchase  must  always  be  presented.
The warranty conditions cannot be honored if the end user

or a third party fail to comply with the corresponding VDE

provisions,  the  provisions  of  the  local  power  supply

companies,  or  our  installation  and  operating  instructions,

as  well  as  the  notes  or  interconnection  diagrams  in  the

configuration documentation, or if the accessories required

from us to implement a function are not used. In the event of

unauthorized  modifications  or  work  performed  by  the  end

user or a third party, the manufacturer is no longer liable for

the  resulting  consequences.  The  warranty  extends  to  the

unit and the parts provided by the supplier. Parts not delivered

by the supplier and unit/system defects attributable to the

use of parts not provided by the supplier do not fall under

warranty  claims.
In so far as we are not able to eliminate the defect, or we

reject  the  rectification  thereof  or  unreasonably  delay  the

implementation  thereof,  the  manufacturer  will  deliver  a

replacement unit free of charge or remunerate the reduced

value.  In  the  case  of  a  replacement  delivery,  we  reserve

the right to make appropriate allowance for the use of the

unit up to this time. Additional or more extensive claims, in

particular such claims resulting the replacement of damage

to objects other than the unit are, provided that liability has

not been compulsorily ordered by law, excluded.

An extension of the warranty to 36 months for heating heat

pumps and central ventilating systems, however a maximum

of 38 months from the date of delivery from the factory, will

be  granted  in  accordance  with  the  following  conditions:

prerequisite  for  the  granting  of  the  extended  warranty  is

the commissioning, subject to cost, by the authorized system

engineering  customer  service,  with  the  commissioning

certificate, within a time of operation (compressor running

time)  of  less  than  150  hours.  Defects  reported  in  the

commissioning certificate must be eliminated without delay.

This  constitutes  the  basis  for  the  warranty.  The

commissioning certificate must be sent to the address below,

from which the warranty period extension is also confirmed,

within one month of successfully commissioning the unit.
The charge for commissioning includes the commissioning

itself and the costs of travel. No liability can be assumed for

proper planning, dimensioning and the performnce of work

on  the  overall  system.  The  elimination  of  defects  in  the

overall  system  and  the  service  times  required  are  special

services.
The commissioning charge, which is currently € 320 net for

heating heat pumps and € 450 net for ventilating systems,

both  per  unit,  is  invoiced  to  the  contractor  by  the  system

engineering customer service. We reserve the right to make

adjustments to these prices.
In the event that customer service is required, the authorized

system  engineering  customer  service  responsible  for  the

customer site must be informed and will provide fast help to

deal with the problem. The authorized system engineering

customer  service  responsible  for  your  region  can  be

determined by contacting the service hotline for the Dimplex

Division of the KKW Kulmbacher Klimageräte-Werk GmbH.
KKW Kulmbacher Klimageräte-Werk GmbH

Dimplex Division

System Engineering Customer Service

Am Goldenen Feld 18

95326 Kulmbach

Germany
Telephone:

+49 (0) 9221 709 562

Fax:

+49 (0) 9221 709 565

e-mail:

[email protected]

[email protected]

Internet:

www.kkw.de

www.dimplex.de

The product number (

E.Nr.

) and the date of production (

FD

)

of the unit are required in order to process the order. This

information is given on the nameplate in the field marked

with  the  heavy  border.

.Customer  service  address

Содержание WI 40CG

Страница 1: ...INSTALLATION and OPERATING INSTRUCTIONS Water Water Heat Pump for indoor installation CE Order No 452225 66 94 FD 8209 WI 40CG WI 90CG...

Страница 2: ...SPORT 5 6 INSTALLATION SITE 6 6 1 General notes 6 2 Sound emission 7 INSTALLATION 6 7 1 Connection of the heating system 7 2 Connection of the heat source 7 3 Connection to power supply 8 STARTUP 8 8...

Страница 3: ...eeded for that purpose 1 2 Legal requirements and guide lines The heat pump complies with all relevant DIN VDE regulations and EEC directives These are listed in the attached CE conformity statement E...

Страница 4: ...stallations Water is used as the heat transfer medium The water may be supplied from a well or similar sources The well water must be of the water quality specified Under normal conditions an intermed...

Страница 5: ...rol cables serve to interconnect the heat pump control and the basic control unit as well as the basic control unit and the terminal box of the heat pump These cables are available in several lengths...

Страница 6: ...LLATION SITE INSTALLATION INSTALLATION 7 1 Connection of the heating system Before connecting the heat pump to the heating system the heating plant should be flushed thoroughly to prevent any particle...

Страница 7: ...r supply All components needed for connecting the electric supply to the heat pump are located in the basic control unit Mount this unit to a smooth wall surface of the building A heat pump control is...

Страница 8: ...ntrol unit Slightly rotate the connector ccw and cw to feel for the anti rotation lock Then insert the connector until the ring nut of the contactor catches Turn the ring nut clockwise to secure the c...

Страница 9: ...at pump due to dirt collections in the heat exchangers Should a malfunction of that type occur clean the unit as described below Disconnect all voltage supplies prior to opening the unit 9 2 Cleaning...

Страница 10: ...ust be closed Please observe the applicable environmental regulations in regard to recycling reuse and disposal of working materials and fluids accord ing to DIN EN 378 when taking the heat pump out o...

Страница 11: ...ristics 90C 1 cond 19 12 3 6 Pressure losses 90C 20 12 4 Circuit diagrams 12 4 1 External basic control unit 40C 21 12 4 2 Load 40C 22 12 4 3 Internal terminal box 40C 23 12 4 4 Terminal assignment in...

Страница 12: ...2 1 1 Heat pump 40C Connections on heating side Connections on heat source side External thread External thread Turning lock Heating water outlet Heat source inlet Heat source outlet Inlet of control...

Страница 13: ...pump 90C ANNEX 12 1 DIMENSIONAL DRAWINGS Connections on heat source side 2 External thread Turning lock Heating water inlet Heating water outlet Heat source inlet Inlet of control cable load cable Hea...

Страница 14: ...V IRU KHDW VRXUFH LQFK RXWVLGH RXWVLGH HLJKW RI WUDQVSRUW XQLW V LQFO SDFNDJLQJ NJ 75 32 5 211 7 21 1RPLQDO YROWDJH IXVHG 9 1RPLQDO SRZHU FRQVXPSWLRQ N 6WDUWLQJ FXUUHQW ZLWK VRIW VWDUWHU 1RPLQDO FXUUH...

Страница 15: ...2 10 8 6 4 2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Soleeintrittstemperatur in C 35 5 Leistungsaufnahme in kW incl der anteiligen Pumpenleistungen Bedingungen Heizwasserdurchsatz 2 9 m h Soledurchsatz 8...

Страница 16: ...Heizwasserdurchsatz 2 9 m h Soledurchsatz 8 4 m h 35 50 0 2 4 6 8 10 8 6 4 2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Kaltwassereintrittstemperatur in C 35 50 Leistungsaufnahme in kW incl der anteiligen...

Страница 17: ...20000 25000 30000 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 Heizwasserdurchflu in m h Druckverlust in Pa Druckverluste Verfl ssiger Sole Wasser 30C bei 10 C Druckverlust 9 kPa bei Heizwasser Nenndurchflu 2 9 m...

Страница 18: ...mpenleistungen 35 5 0 5 10 15 20 25 10 8 6 4 2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Soleeintrittstemperatur in C 35 5 Leistungsaufnahme in kW incl der anteiligen Pumpenleistungen Bedingungen Heizwasse...

Страница 19: ...eizwasserdurchsatz 6 0 m h Soledurchsatz 16 0 m h 35 50 0 2 4 6 8 10 12 10 8 6 4 2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Kaltwassereintrittstemperatur in C 35 5 Leistungsaufnahme in kW incl der anteili...

Страница 20: ...000 10000 15000 20000 0 1 2 3 4 5 6 7 8 9 10 Heizwasserdurchflu in m h Druckverlust in Pa Druckverluste Verfl ssiger Sole Wasser 70C bei 10 C Druckverlust 6 kPa bei Heizwasser Nenndurchflu 6 0 m h Pre...

Страница 21: ...X12 4 X11 3 X1 22 1 4 2 T X2 16 F6 X2 15 X12 6 X1 20 X1 21 3 A5 13 X8 1 Q1 14 X8 2 4 13 Verd 1 13 32 4 44 6 32 4 43 2 3 4 4 3 5 22 3 6 3 5 14 5 3 1 21 13 31 2 3 4 4 3 5 22 3 K14 14 6 3 5 41 41 42 31 4...

Страница 22: ...Bl 4 X2 4 5 6 PE X1 PE 2 3 V U W N 7 4 5 6 U V W N 8 Soleumw lzpumpe optional 3 M X1 PE 4 7 8 9 K2 2 4 6 S R 2 4 1 3 T 6 K5 5 2 4 1 3 6 F8 5 R S T 2 4 6 K14 1 3 5 F9 2 4 6 1 3 5 13 3 2 5A 21 3 1 5 Q 1...

Страница 23: ...5 1 N 11 14 N PE 2 C A B 16 PE 18 17 19 PE P HD W chter F2 A C B 20 22 21 PE Zubeh r Steuerleitung 14 12 15 6 10 1 4 5 Bl 1u 2 X8 X11 15 X4 2 11 3 12 4 3 Heat pump 40C ANNEX 12 4 CIRCUIT DIAGRAMS Cabl...

Страница 24: ...t PE L L L 1 4 2 3 M 1 PE PE L N X1 1 2 M 3 Verdichter M 2 3 PE 5 4 6 9 7 8 PE 11 PE 12 PE N N 11 12 PE X12 Anschlusskasten W rmepumpe W rmepumpenregler X11 Steuerleitung 21 A5 13 14 15 16 17 18 19 20...

Страница 25: ...pressure fault K2 Contactor for well pump K5 Contactor for condenser 1 K14 Contactor for condenser 2 K15 Relay condenser 1 K16 Relay condenser 2 K17 Time relay flow switch K11 EVU blocking contactor M...

Страница 26: ...1 18 16 13 K14 5 3 1 14 5 3 1 13 K5 1 31 32 3 43 44 2 2 3 4 2 3 6 2 3 2 2 6 4 2 7 6 2 7 18 K15 12 14 5 3 1 14 K14 1 K15 1 15 5 16 21 5 2 2 6 4 2 6 6 2 6 14 12 K14 1 16 16 18 18 A1 A2 A2 A1 K14 A1 A2...

Страница 27: ...U V W 2 1 7 X1 7 PE 8 9 2 4 R S T 1 3 5 2 4 6 2 K5 1 4 1 3 1 5 I I 3 1 6 K5 I I 5 1 5 I 14 12 1 6 1 3 5 Q 3 11 K3 K2 Bl 4 X2 4 5 6 PE 4 1 2 1 7 X1 PE 6 1 2 4 5 6 F13 N 8 V U W M4 M 3 4 1 2 71 X1 PE 9...

Страница 28: ...1u 2 X8 X11 30 31 32 21 20 22 19 18 Elektronischer Wicklungsschutz Verdichter 2 F2 HD W chter R ckstellung selbstt tig F3 P P A C B C B R F11 F5 Verdichter 1 N L N L F11 F5 M2 M2 Verdichter 2 Verdich...

Страница 29: ...usskasten W rmepumpe M 3 M 1 Verdichter M 2 M 3 X12 W rmepumpenregler Anschlusskasten W rmepumpe Steuerleitung Steuerleitung N3 X8 X11 X4 12 4 9 Terminal assignment incl heat pump control 90C ANNEX 12...

Страница 30: ...r condenser 2 K14 1 Starter contactor for condenser 2 K15 Relay for condenser 1 K15 1 Time delay relay K5 K16 Relay for condenser 2 K16 1 Time delay relay K14 M1 Condenser 1 M2 Condenser 2 M3 Well pum...

Страница 31: ...2 Heating circulating pump 5 Hot water circulating pump 12 Expansion vessel 15 Flexible connection hoses 16 Structure borne noise insulation 17 Non return valve 18 Overflow valve 19 Thermostat valve 2...

Страница 32: ...EN 378 1994 DIN EN 603335 1 VDE 0700 part I 1995 10 EN 60335 1 1994 A11 1995 WI 40CG DIN EN60335 1 A1 VDE 0700 part 1 A1 1997 08 EN 60335 1 A1 1996 WI 90CG DIN EN 60335 1 A12 VDE 0700 part 1 A12 1997...

Страница 33: ...o not fall under warranty claims In so far as we are not able to eliminate the defect or we reject the rectification thereof or unreasonably delay the implementation thereof the manufacturer will deli...

Страница 34: ...34 Notes...

Страница 35: ...35 Notes...

Страница 36: ...36 KKW Kulmbacher Klimager te Werk GmbH Technical modifications reserved Dimplex Division Telefax 0 92 21 709 589 Am Goldenen Feld 18 www dimplex de D 95326 Kulmbach Germany...

Отзывы: