WI 10TU - WI 22TU
Type and order code
WI 18TU
WI 22TU
1
Design
Heat source
Water
Water
1.1
model
Universal
Universal
1.2
Contr.
WPM EconPlus
WPM
EconPlus
1.3
Thermal energy metering
Integrated
Integrated
1.4
Installation location
Indoors Indoors
1.5
Performance levels
1
1
2
Operating limits
2.1
Heating water flow
°C
20 to 62 ± 2
20 to 62 ± 2
2.2
Cold water (heat source)
°C
+7 to +25
+7 to +25
3
Flow / sound
3.1
Heating water flow at internal pressure differential
Nominal flow according to EN14511 at W10-7 / W35-30
m³/h / Pa
at W10-7 / W45-40
m³/h / Pa
at W10-7 / W55-47
m³/h / Pa
Minimum heating water flow
m³/h / Pa
2.9 / 16200
2.7 / 14100
1.6 / 5100
1.6 / 5100
3.8 / 22900
3.6 / 20700
2.2 / 7700
2.2 / 7700
3.2
Cold water flow at internal pressure differential
Nominal flow according to EN14511 at W10-7 / W35-30
m³/h / Pa
at W10-7 / W45-40
m³/h / Pa
at W10-7 / W55-47
m³/h / Pa
Minimum cold water flow
m³/h / Pa
4.0 / 15200
3.4 / 11200
3.3 / 10500
3.3 / 10500
5.3 / 21400
4.7 / 17100
4.0 / 12100
4.0 / 12100
3.3
Sound power level according to EN 12102
1
dB(A)
1. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can deviate by up to 3dB(A).
44
47
3.4
Sound pressure level at a distance of 1 m
2
dB(A)
2. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
32
35
4
Dimensions, connections and weight
4.1
Device dimensions
3
H x W x D mm
3. Please note that additional space is required for pipe connections, operation and maintenance.
840
650 x 655
840
650 x 655
4.2
Weight of the transportable unit(s) incl. Packaging/full
kg
160
179
4.3
Device connections for heating system
Inches
4
4. Flat-sealing
Thread 1¼" external
Thread 1¼" external
4.4
Device connections for heat source
Inches
Thread 1¼" external
Thread 1½" external
4.5
Refrigeran / total filling weight
type/kg
R410A/3.4
R410A / 4.0
4.6
GWP value / CO
2
equivalent
--- / t
2088 / 7
2088 / 8
4.7
Refrigeration circuit hermetically sealed
yes
yes
4.8
Lubricant / total filling quantity
type/litres
Polyolester (POE)/1.2
Polyolester (POE) / 1.9
4.9
Volume of heating water in device
Litres
4.5
5.6
4.10 Volume of heat transfer medium in device
Litres
2.9
3.3
5
Electrical connection
5.1
Supply voltage / fuse protection Compressor
Primary circulating pump
Joint supply
Compressor and primary circulating pump
3~/PE 400 V (50 Hz) / C13 A
3~/PE 400 V (50 Hz) / C10 A
3~/PE 400 V (50 Hz) / C13 A
3~/PE 400 V (50 Hz) / C16 A
3~/PE 400 V (50 Hz) / C10 A
3~/PE 400 V (50 Hz) / C16 A
5.2
Control voltage / fuse protection
1~/N/PE 230 V (50 Hz) / C13 A
1~/N/PE 230 V (50 Hz) / C13 A
5.3
Degree of protection according to EN 60 529
IP 21
IP 21
5.4
Starting current with soft starter
A
23
28
5.5
Nominal power consumption W10/W35/max. consumption
5
kW
5. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and oper-
ation can be found in the respective sections of the installation and operating instructions. The specified values, e.g. W10 / W35, have the following meaning: Heat source
temperature 10 °C and heating water flow temperature 35 °C.
2.95 / 5.4
3.91/ 7.2
5.6
Nominal current W10/W35/cos
A / --
5.32 / 0.8
7.06 / 0.8
5.7
Power consumption of compressor protection (per compressor)
W
thermostatically controlled
thermostatically controlled
6
Complies with the European safety regulations
6
6. See CE declaration of conformity
7
Additional model features
7.1
Water in device is protected against freezing
7
7. The heat circulating pump and the heat pump manager must always be ready for operation.
Yes
Yes
7.2
Max. operating overpressure (heat source/heat sink)
bar
3.0
3.0
8
Heat output / COP
Heat output / COP
EN 14511
EN 14511
Performance level
1
2
1
2
at W10 / W55
kW / ---
15.1 / 3.6
20.0 / 3.6
at W10 / W45
kW / ---
15.6 / 4.4
21.1/ 4.4
at W10 / W35
kW / ---
17.1 / 5.8
22.3 / 5.7