Faults
English
11.2. Fault messages
Deleting fault messages
All fault messages, with the exception of the window
symbol, can be deleted as follows:
Disconnect the power supply completely.
Remove the cause of the error.
Restore the power supply.
Delete the window monitoring fault message
Disappears automatically after 60 minutes if the
room temperature rises.
Disappears automatically following a switch from
comfort mode to energy saving mode. See "User
main menu" on page 18.
Press the ENTER key for 15 seconds.
ATTENTION!
Storage heaters may only be repaired by
qualified specialists. Repairs which are im
-
properly carried out can endanger the safety
of the user.
NOTE
i
The devices have a high-grade thermal insulation.
Only remove the core room cover with integrated
thermal insulation when exchanging the heating ele
-
ments. All other electrical components can be ac
-
cessed by removing the side panels.
11.3. Resetting the temperature limiter
Allow the device to cool down sufficiently.
Open the side panel, See "Installation" on page 9.
Actuate the reset pin with a screwdriver blade.
Mount the side panel again.
11.4. Disposal
ATTENTION!
The storage heater must be de-energized
before decommissioning and disassembly.
ATTENTION!
The storage heater may only be disassem
-
bled by an electrician.
These devices are free from asbestos and can be
completely dismantled without concerns.
According to the Electrical Equipment Act,
storage heaters must not be disposed of as
household waste, but must be taken to a
local disposal point.
Please store removed storage stones in a
dry place throughout the entire disposal chain, as
trace elements may otherwise enter the groundwater.
Display
Cause
Measures required
The window
symbol
flashes
Windows or doors are open. The area is
draughty.
Close window. Prevent draughts, e.g. keep doors closed,
turn off fans.
E20
Room sensor or main electronics faulty
Contact the service team.
E21
Core sensor or main electronics faulty
Contact the service team.
E30
Ambient temperature unusually high
Remove the cause of the unusually high ambient tem
-
perature.
E34
Core temperature exceeded,
fan motor without function
Contact the service team.
E40
Communication fault between the operating
panel and main electronics
Check the connection cable between the operating
panel - main electronics. Contact the service team.
E62
Service menu
Signal at terminals A1+/A2- or A1~/A2~
absent or faulty.
Checks signals at A1+/A2- or A1~/A2~. Check settings
P9 in the installer menu.
E63
Service menu
No charge release
Check settings in the installer menu.
See "P13 – Release manual" on page 16.