THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
DO NOT COVER OR OBSTRUCT the air inlet or outlet
grille.
IMPORTANT – Disconnect from the mains supply
before carrying out maintenance work.
THIS APPLIANCE MUST BE EARTHED
This heater must not be located immediately above
or below a fi xed socket outlet or connection box.
Keep combustible materials such as drapes and
other furnishings clear from the front, sides and rear
of the heater.
DO NOT use this heater in the immediate surrounding
of a bath, a shower or a swimming pool.
DO NOT use this heater in areas where excessive
dust exists.
This appliance is not intended for use by children
or other persons without assistance or supervision
if their physical, sensory or mental capabilities
prevent them from using it safely. Children should
be supervised to ensure that they do not play with
the appliance.
The heater carries the Warning symbol
indicating that it must not be covered.
The instruction leafl et belongs to the appliance and
must be kept in a safe place. If changing owners, the
leafl et must be surrendered to the new owner.
IMPORTANT – If the mains lead of this appliance is
damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualifi ed person in
order to avoid a hazard.
Ensure proper manual handling procedures are
observed at all times.
General
SRX180
SRX140
SRX120
SRX80
Heat
Output*
(kW)
2
1800
1400
1200
800
Dimensions
L x H x D
(mm)
911x500x145 740x500x145 670x500x145 503x500x145
Power Input
(W)
3
50-53
56-60
43-47
26-27
2
33-35
36-40
29-32
19-20
1
23-24
24-26
20-22
16-17
Air Flow
Rate
(m
3
/hr)
3
540
410
345
228
2
300
225
190
125
1
160
120
100
60
Sound
Level @ 1m
dB(A)
3
47
47
47
47
2
38
38
38
38
1
27
27
27
27
Voltage
(V)
~230-240
~230-240
~230-240
~230-240
* Rated Output at 45°C at medium fan setting.
UK
- 1 -
Dimplex SmartRad
Models: SRX80, SRX120, SRX140 & SRX180
The SmartRad convector is an intelligent convector designed
for use on central heating systems in homes and commercial
environments. The convector is optimised to work with the
Dimplex range of heat pumps and also works effi ciently on
standard oil or gas fi red central heating systems.
Some of the appliance’s features are highlighted in Fig.1.
(a) Aesthetic Front Panel
(b) Thermostat/ Fan selector Panel
(c) Metal air outlet grille
(d) 1m long cable
To ensure optimum performance consideration must be
given to the size of fan convector and the heating system
design. The following should be considered:
These appliances have to be only used on closed
•
circulation, two pipe central heating systems.
Appliances should be correctly sized to match the heat
•
loss requirements of the room. Kitchens, living areas etc,
should be based on the medium setting, while bedrooms
should be based on the low speed.
Installation Instructions.
Unpack the appliance.
Remove all packaging from the appliance. Remove the four
fi xing screws at the bottom of the appliance as shown in
Fig. 2 to release the front cover. Put the front cover to one
side to avoid damage during installation.
Wall mounting.
Using the Fig 3, mark off and drill four holes in a suitable
solid wall. Insert the wall plugs (provided) into all the holes.
Screw in the top two screws to almost full way. Hang the
appliance on these top screws. Screw in the bottom two
screws to secure. Tighten the top screws. For drywalls,
use suitable wall plugs (not supplied) and repeat as above.
The appliance should be securely mounted to the wall to
mimimise the possibility of noise transmission.
Water connection.
The heating system should be capable of supplying hot
water to the appliance. Therefore the following should be
noted
The minimum pipe work should be 15mm
–
Appliances are not suitable for use on microbore pipes
–
Appliances are not suitable for use on one pipe
–
systems.
Where the appliance is fi tted onto a system with other
–
emitters, a separate circuit for the appliances should be
considered to ensure an adequate water fl ow through
it.
Optimum performance of the appliance will require
–