E-8
English
12
12 Device Information
Device information for brine-to-water heat pumps for heating purposes
1
Type and order code
SI 30CS
SI 70CS
2
Design
2.1
Degree of protection according to EN 60 529
IP24
IP24
2.2
Installation Location
Indoors
Indoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow
°C
Up to 55
Up to 55
Brine (heat source)
°C
-5 to +25
-5 to +25
Antifreeze
Monoethylene glycol
Monoethylene glycol
Minimum brine concentration (-13 °C freezing temperature)
25 %
25 %
3.2
Temperature spread of heating water at B0 / W35K
9.6
9.7
3.3
Heat output / COP
at B-5 / W55
1
kW / ---
2
1. This data indicates the size and capacity of the system according to EN 255. For an analysis of the economic and energy efficiency of the system, both the bivalence point and
the regulation should also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow
temperature 55 °C.
2. Operation with 2 compressors
27.8 / 2.4
58.5 / 2.4
kW / ---
3
3. Operation with 1 compressors
10.6 / 1.8
26.8 / 2.2
at B0 / W50
1
kW / ---
2
31.5 / 2.9
67.2 / 3.0
kW / ---
3
16.0 / 3.3
35.0 / 3.1
at B0 / W35
1
kW / ---
2
32.4 / 4.1
67.8 / 4.1
kW / ---
3
17.6 / 4.4
37.2 / 4.4
3.4
Sound power level
dB(A)
59
69
3.5
Heating water flow with an internal pressure
differential of
m³/h / Pa
2.9 / 9000
6.0 / 6000
3.6
Brine throughput with an internal pressure
differential (heat source) of
m³/h / Pa
8.4 / 15000
16.0 / 12500
3.7
Refrigerant; total filling weight
type / kg
R407C / 6.7
R407C / 12.0
3.8
Lubricant; total filling weight
type / litres
Polyolester (POE) / 3.54
Polyolester (POE) / 8.2
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4
H x W x L mm
4. Note that additional space is required for pipe connections, operation and maintenance.
830 x 1480 x 890
830 x 1480 x 890
4.2
Device connections to heating system
Inch
G 1 1/4'' external
G 2'' external
4.3
Device connections to heat source
Inch
G 1 1/2'' external
G 2'' external
4.4
Weight of the transportable unit(s) incl. packing
kg
299
450
5
Electrical Connection
5.1
Nominal voltage; fuse protection
V / A
400 / 35
400 / 63
5.2
Nominal power consumption
1
B0 W35
kW
7.82
16.34
5.3
Starting current with soft starter
A
26
60
5.4
Nominal current B0 W35 / cos
ϕ
5)
A / ---
14,1 / 0,8
29,8 / 0,8
5.5
max. power consumption of compressor protection
(per compressor)
W
70
70
6
Complies with the European safety regulations
5
5. See CE declaration of conformity
5
7
Additional model features
7.1
Water in device protected against freezing
6
6. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
Yes
7.2
Performance levels
2
2
7.3
Controller internal/external
External
External