12 Device information
1
Type and order code
SI 26TU
SI 35TU
2
Design
Heat source
Brine
Brine
2.1
Model
Universal
Universal
2.2
Controller
integrated
integrated
2.3
Thermal energy meter
Integrated
Integrated
2.4
Installation location
Indoors
Indoors
2.5
Performance levels
2
2
3
Operating limits
3.1
Heating water flow
1
2
°C
20 to 62 ± 2
20 to 62 ± 2
3.2
Brine (heat source)
1
2
°C
-5 to +25
-5 to +25
3.3
Antifreeze
Monoethylene glycol
Monoethylene glycol
3.4
Minimum brine concentration (-13 °C freezing temperature)
25 %
25 %
4
Flow / sound
4.1
Heating water flow / free compression (max).
Nominal flow in accordance with EN 14511at B0...-3 / W35...30
m³/h / Pa
4,5 / 69000
6,1 / 50000
at B0...-3 / W45...40
m³/h / Pa
4,4 / 72000
5,7 / 52000
at B0...-3 / W55...47
m³/h / Pa
2,7 / 100000
3,5 / 82000
Minimum heating water flow
m³/h / Pa
2,7 / 100000
3,5 / 82000
4.2
Brine flow rate / free compression (max).
Nominal flow in accordance with EN 14511at B0...-3 / W35...30
m³/h / Pa
6,4 / 31000
8,2 / 64000
at B0...-3 / W45...40
m³/h / Pa
5,6 / 43000
7,3 / 72000
at B0...-3 / W55...47
m³/h / Pa
4,9 / 54000
6,4 / 82000
Minimum brine flow rate
m³/h / Pa
4,9 / 54000
6,4 / 82000
4.3
Sound power level according to EN 12102
dB(A)
57
58
4.4
Sound pressure level at a distance of 1m
3
dB(A)
41
42
5
Dimensions, weight and filling quantity
5.1
Device dimensions
4
H x W x L mm
885 x 1000 x 810
885 x 1000 x 810
5.2
Weight of the transportable unit(s) incl. packaging
kg
275
315
5.3
Device connections for heating
inches
G 1½“ external thread
G 1½“ external thread
5.4
Device connections for heat source
Inches
G 1½“ external thread
G 1½“ external thread
5.5
Refrigerant / total filling weight
type/kg
R410A / 8.4
R410A / 10.9
5.6
Lubricant / total filling quantity
type/litres
Polyolester (POE)/2.9
Polyolester (POE)/4.2
5.7
Volume of heating water in device
Litres
7
9
5.8
Volume of heat transfer medium in device
Litres
7
9
6
Electrical connection
6.1
Supply voltage / fuse protection / RCD-Type
3~/PE 400 V (50 Hz) / C 20A / A
3~/PE 400 V (50 Hz) / C 32A / A
6.2
Control voltage / fuse protection / RCD-Type
1~/N/PE 230 V (50 Hz) / C 13A / A 1~/N/PE 230 V (50 Hz) / C 13A / A
6.3
Degree of protection according to EN 60 529
IP 21
IP 21
6.4
Starting current with soft starter
A
23
30
6.5
Nominal power consumption B0 W35 / max. power consumption
5
kW
5,45 / 10,0
7,25 / 14,5
6.6
Nominal current B0 W35 / cos
A / ---
9,83 / 0,8
13,08 / 0,8
6.7
Power consumption of compressor protection
(per compressor)
W
70 / thermostatically controlled
70 / thermostatically controlled
6.8
Power consumption of pumps
kW
up to 0.35
up to 0.5
Содержание SI 26TU
Страница 2: ......
Страница 16: ...DE 14 452237 66 01 FD 9603 www dimplex de Deutsch SI 26TU SI 35TU...
Страница 48: ...A VIII 452237 66 01 FD 9603 Anhang Appendix Annexes SI 26TU SI 35TU 3 3 Last Load Charge SI 26TU...
Страница 54: ...A XIV 452237 66 01 FD 9603 Anhang Appendix Annexes SI 26TU SI 35TU 3 8 Steuerung Control Commande SI 35TU...
Страница 55: ...www dimplex de 452237 66 01 FD 9603 A XV Anhang Appendix Annexes SI 26TU SI 35TU 3 9 Last Load Charge SI 35TU...
Страница 65: ...www dimplex de 452237 66 01 FD 9603 A XXV Anhang Appendix Annexes SI 26TU SI 35TU...
Страница 66: ...A XXVI 452237 66 01 FD 9603 Anhang Appendix Annexes SI 26TU SI 35TU...
Страница 67: ...www dimplex de 452237 66 01 FD 9603 A XXVII Anhang Appendix Annexes SI 26TU SI 35TU...