Installation Instructions
ImpoRTanT InSTRucTIonS
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock
and injury to person, including the following:
Read all instructions before using this heater.
1.
A heater has hot and arcing or sparking parts inside. Do
2.
not use it in areas where gasoline, paint or flammable
liquids are used or stored.
This heater is hot when in use. To avoid burns, do not let
3.
bare skin touch hot surfaces. If provided, use handles
when moving this heater. Keep combustible materials
such as: furniture, pillows, bedding, papers, clothes and
curtains away from heater.
To prevent a possible fire, do not block air intakes or
4.
exhaust in any manner. Do not use on soft surfaces like
a bed where openings may become blocked.
Do not insert or allow foreign objects to enter any venti-
5.
lation or exhaust opening as this may cause an electric
shock or fire, or damage the heater.
Save THeSe InSTRucTIonS
Congratulations on purchasing a small wall heater from
Dimplex North America. Your heater is manufactured using
the highest quality materials and workmanship and will
provide many years of trouble free service.
This heater is designed for permanent installation only.
Care should be taken to install according to the following
instructions. All required clearances should be maintained.
In addition all electrical wiring and connections should
comply with local electrical codes.
!
noTe:
It is extremely important to read all information
labels. Care must be taken to ensure that the heater is
rated the same voltage as the electrical supply wires.
Failure to do so could result in unsafe heater operation as
well as damage to the unit. If replacing an existing heater,
check the labels of the old heater to ensure the voltage of
the new heater is compatible.
All units should be controlled by means of a regulating
thermostat. Certain models only are provided with built in
thermostats. Check the
Model Key Information
section for
verification. Wall thermostats should comply with the voltage
and wattage of all heaters on the circuit. Built in thermostats
are not suitable for Register Grille Models.
All installations require the following components:
1) Recess Mount Box (Model 1011650100)
2) Heater Assembly (See nameplate Label)
3) Grille (Either Multi- Directional Style or Register Style)
An optional Surface Mount Box is available for installations
that are not recessed in wall cavity.
multi-Directional Grille orientation
Figure 1
Recess Box
Wiring Access
Figure 2
Alternate Multi-Directional Grille Orientation
!
noTe:
Maintain a minimum clearance of 8” from adjacent
walls, floors and ceilings on all four sides of the grille
Register Grille
Orientation
Step 1 – placement
All units are designed for placement in either interior or
exterior walls. Care should be taken to provide a minimum
of 8" clearance from floors, ceilings and adjacent walls.
Once installed, the airflow through the heater should not be
blocked in any way. Maintain 3’ (91.4cm) clearance of objects
from the front of unit. Maintain a spacing of 3’ (91.4cm)
between heaters in order to prevent re-circulation of heated
air. Insulation surrounding the back and sides of the recess
mount box will not affect performance. Ensure insulation is
rated for temperatures up to 185°F (85°C).
!
noTe:
Certain flooring and wall covering materials
(particularly those incorporating clear vinyl materials tend
to distort at temperatures in the vicinity of 140°F (60°C).
Material shall be checked prior to installation to determine
if discoloration will occur. Units are not approved for
placement in floors or ceilings. Do not install in any area
where combustible vapors, gases, dusts or liquids are
present. Fire or explosion may occur.
Step 2 – mounting The Recess Box
Determine the desired orientation of unit. Provide an
opening in wall 14 ¼” x 8 1/8" x 3 3/8" (36.2cm x 20.6cm