Waking from Standby Mode
When in standby mode, holding
ENTER
for two seconds will wake the remote and
attempt to reconnect to the product, this will be signified by the connectivity icon
and loading graphic appearing on the screen.
The remote control provides the option of a number of standard control modes,
•
Timer Mode:
provides the greatest flexibility to the user. Four heating periods are
available throughout each day and these can be customised for every day of the
week. The desired set temperature can be set for each time slot independantly
•
Manual Mode:
Maintains the displayed temperature for an undetermined period.
The default ‘comfort’ temperature in manual mode is set to 21°C however this can
be adjusted to suit.
•
Frost Protect:
maintains a room temperature of 7°C. This mode should be used to
provide protection against frost.
•
Comfort Off:
no room temperature control
There are also a number of advanced control options and features available
•
Runback Mode:
This is an additional feature available to manual mode, with this
mode active the manual mode will operate for a determined time period and then
revert to Comfort Off mode.
•
Setback Mode:
This is an additional feature available to timer mode, with this mode
active the appliance will control the room to a pre-set temperature during timer
‘off’ periods.
•
Open Window Mode:
This is a global setting that can interrupt any active mode.
Activating this setting enables
Open Window Detection
to switch the Heater to a
Heating Off
state if it detects an open window in the room it’s operating
•
PIN Lock Mode:
This mode will lock the appliance in the existing mode and will only
allow some basic functions to operate. Once activated, in order to change settings
the user must input a pre-set PIN. This is ideal where it is desired to limit the use
and functionality of the appliance.