Coverage for Spot Heating Applications
The area heated by a Quartz Halogen Heater depends on the height and the angle at
which the heater is mounted.
For 30° Heater Mounting Angle:
Area Covered
= (Height)² x 2.66
Average Width of Beam = Height x 2.0
Throw of Beam
= Height x 1.33
For 45° Heater Mounting Angle:
Area Covered
= (Height)² x 5.72
Average Width of Beam = Height x 2.2
Throw of Beam
= Height x 2.6
Model No.
QXD1500E
QXD3000E
QXD4500E
Average Radiant
Intensity on
Heated Area (W/
m²)
Height
(m)
Throw
(m)
Spread
(m)
Height
(m)
Throw
(m)
Spread
(m)
Height
(m)
Throw
(m)
Spread
(m)
Angled 30° from vertical
150
2.9
2.5
3.8
3.7
3.6
5.4
4.4
4.4
6.7
200
2.7
2.2
3.3
3.4
3.1
4.7
3.9
3.8
5.8
250
2.5
2.0
3.0
3.1
2.8
4.2
3.6
3.4
5.2
Angled 45° from vertical
150
2.3
3.4
2.9
2.9
4.9
4.2
3.3
5.6
5.0
200
2.1*
2.9
2.4
2.6*
4.1
3.5
3.0*
5.2
4.4
NOTE: 1. Intensity is average intensity in W/m² based on Wattage of heater and
area covered and measured on a horizontal plane 1m above the floor level.
2. Heater mounting heights are in metres and are above floor level. Those
marked ‘*’ are minimum mounting heights for the particular heater model.
3. Throw and spread figures are in metres.
Height