08/54003/0   ISSUE: 1

Quartzray Infrared Heater

Models:  QXD1500E / QXD3000E / QXD4500E

INSTRUCTION MANUAL

Installation and Operating

This product is supplied and operated with a Bluetooth Remote Control handset

Содержание QXD1500E

Страница 1: ...8 54003 0 ISSUE 1 Quartzray Infrared Heater Models QXD1500E QXD3000E QXD4500E INSTRUCTION MANUAL Installation and Operating This product is supplied and operated with a Bluetooth Remote Control handse...

Страница 2: ...d level 5 to the horizontal Do not locate the heater immediately above or below a fixed socket outlet or connection box This heater must not be located immediately above or below a fixed socket outlet...

Страница 3: ...given where children and vulnerable people are present Always disconnect the heater from the electricity supply and leave to cool for a minimum of 30 minutes before attempting to work on or near it A...

Страница 4: ...n the electrical installation should include earth continuity and insulation tests and must be undertaken by a competent person Ensure that all the electrical connections at the lamps and the terminal...

Страница 5: ...MOVE SCREWS TERMINAL COVER BOX MUST SLIDE OUT FIRST THEN UP Fig 2 TRIM POWER SUPPLY CABLE SHEATH SO THAT LIVE NEUTRAL AND EARTH WIRES ARE AT A SUITABLE LENGTH TIGHTEN CABLE SADDLE CLAMP ONTO END OF PO...

Страница 6: ...the ends from the spring clips Keep the lamp secure and do not twist the ends or apply undue force IMPORTANT Release and retain the high temperature cable ties from the element wires These must not be...

Страница 7: ...ternal pressure in excess of atmospheric pressure and while construction is very strong there is a slight risk of shattering If it is necessary to examine a bare lamp whilst in operation then a protec...

Страница 8: ...3 0kW 4 5kW Auxiliary electricity Consumption At nominal heat output elmax 0 00 0 00 0 00 At minimum heat output elmin 0 00 0 00 0 00 In standby mode elSB 0 0005 0 0005 0 0005 Type of heat output room...

Страница 9: ...losure Finish Colour Powder coated steel finished in Matte Black Element Ruby halogen element Installation Supplied with wall mounting bracket Safety No cut out on board Protection via RCD IP Rating N...

Страница 10: ...s and are suitable for use on 230 240V and 415V 3N supplies Model No No of Lamps Rating kW Voltage V Weight kg QXD1500E 1 1 5 230 240 3 7 QXD3000E 2 3 0 230 240 4 3 QXD4500E 3 4 5 230 240 5 8 Material...

Страница 11: ...Allow a minimum of 0 5 metre clearance between the top of the heater and the ceiling Dimension C on the appliance rating label Allow a minimum of 1 5 metre clearance between the edge of heater and the...

Страница 12: ...tected by fuses to the following rates Wiring between the heater and the spur outlet or isolation switch must be in a heat resisting cable e g butyl rubber or high temperature PVC insulated Sufficient...

Страница 13: ...Wiring Diagrams QXD4500E Single Phase Note Links bridging L1 L2 and L3 must be fitted QXD4500E Three Phase Note Links bridging L1 L2 and L3 must be removed 13...

Страница 14: ...QXD3000E QXD1500E 14...

Страница 15: ...Height m Throw m Spread m Height m Throw m Spread m Height m Throw m Spread m Angled 30 from vertical 150 2 9 2 5 3 8 3 7 3 6 5 4 4 4 4 4 6 7 200 2 7 2 2 3 3 3 4 3 1 4 7 3 9 3 8 5 8 250 2 5 2 0 3 0 3...

Страница 16: ...e the appliance When paired with the remote control various operational modes and features can be accessed IMPORTANT NOTE The remote control is required to operate the appliance It is important that t...

Страница 17: ...ve been successfully fitted the remote control will immediately start scanning for a product to control At this stage it is necessary to complete the pairing process see Remote Pairing Instructions Re...

Страница 18: ...e ensure that no other products are broadcasting within the vicinity to prevent pairing to the incorrect product 3 The remote will search for devices for 1 minute If no product can be found the remote...

Страница 19: ...remote will automatically move to the date setting 1 After confirming the last time digit Day will blink three times and then change to a two digit number with the first digit blinking This two digit...

Страница 20: ...20...

Страница 21: ...4 5 Arrow keys used to navigate through the menus and adjust the room temperature set point 6 ADV use depends on the active mode and settings typically used to advance the program in timer mode or to...

Страница 22: ...inst frost Comfort Off no room temperature control There are also a number of advanced control options and features available Runback Mode This is an additional feature available to manual mode with t...

Страница 23: ...rwise OFF will be displayed Active mode display the active mode of operation is displayed at the bottom of the screen Sleep mode when the remote is left inactive the remote display will sleep turning...

Страница 24: ...selected you may be prompted for further action see relevant section relating to this mode The heater is fitted with an adjustable electronic thermostat enabling the room temperature to be controlled...

Страница 25: ...hold the ADV button for 2 seconds The remote will enter the heat selection screen Use the arrow keys to navigate to the desired setting and confirm using the ENTER key The remote will return to the h...

Страница 26: ...fort of this heating mode Activating the Timer To activate the Timer mode Press the MENU key from the home screen Use the arrow keys to highlight the Schedule Icon Press ENTER to enter Timer Settings...

Страница 27: ...is confirmed the remote will automatically enter the set point setting screen Use the arrow keys to set the desired set point temperature confirm using the ENTER key The Off time should then be set us...

Страница 28: ...y for 2 seconds COPY will flash on screen to show it has copied Use the arrow key to highlight the day to which you wish to copy the profile Hold the ENTER key for 2 seconds PSTE will flash on the scr...

Страница 29: ...within the Heater s Temperature Range Frost Protection Default 7 C Can be changed from the Home Screen to any value however once the temperature is changed the unit will revert to a standard Manual m...

Страница 30: ...et point reached 7 C NOTE If the temperature is raised in Frost Protect the product will automatically enter Manual Mode Comfort Off When activated this appliance will provide no room temperature cont...

Страница 31: ...have the heating on If the remote displays OFF Schedule Icon or no target temperature and heat is required press the ADV button If the remote displays ON and heat is not required press the ADV button...

Страница 32: ...desired the additional runback duration periods can be accessed by pressing the ADV button There will be four runback time durations available to select from Continue pressing Advance until the desire...

Страница 33: ...ion The advanced menu options are Runback Setback Open Window Detection PIN lock Runback Settings This menu is used to activate the runback function and also setup the main function parameters see Run...

Страница 34: ...select the desired Runback temperature Press ENTER to activate the Runback timer and return to the home screen Maximum Runback Duration Selectable Runback options Period 1 Period 2 Period 3 Period 4 0...

Страница 35: ...nd for heat Heating On To activate and setup setback mode Hold the ADV and MENU buttons for 2 seconds Use the arrow keys to highlight Sb and confirm using the ENTER key Use the arrow keys to select Se...

Страница 36: ...the Window icon will be visible on the home screen In the event of an open window being detected holding down ENTER for 2 seconds will clear the error from the screen See page 43 for information on e...

Страница 37: ...he appliance will continue to control to the pre set comfort on temperature Runback mode is not available Frost protect All functionality will be disabled the appliance will continue to provide frost...

Страница 38: ...irst digit Press ENTER to confirm Repeat until all four digits have been entered then press ENTER to confirm If the correct PIN has been entered the device will be unlocked and you will be returned to...

Страница 39: ...will be visible on the home screen In the event of an open window being detected holding down ENTER for 2 seconds will clear the error from the screen See page 43 for information on error screens Open...

Страница 40: ...roll through the information pages Once all the information screens have been viewed the remote will return to the home screen Alternatively if idol for 5 seconds the screen will return to the home sc...

Страница 41: ...he Bluetooth remote Hold down Up and Down buttons at the same time for 5 seconds to enter Fr Factory Reset options Use the arrow keys to toggle factory reset Heater h or Remote r and press ENTER to co...

Страница 42: ...oth remote control will automatically reconnect with the product However the time and date settings on the handset will have been lost and must be reset for time profiles to function correctly IMPORTA...

Страница 43: ...t should not be disposed of with household waste Please recycle where facilities exist Check with a Local Authority or retailer for recycling advice in your country Batteries should be disposed of or...

Страница 44: ...ct its serial number and a description of the fault which has occurred You can find the model number and serial number for your Dimplex product on the heaters side Once we receive your information and...

Страница 45: ...original receipt as proof of purchase and if required by Dimplex proof of delivery If you are unable to provide this documentation you will be required to pay for any repair work required Any repair...

Страница 46: ...46...

Страница 47: ...47...

Страница 48: ...co uk Glen Dimplex Heating and Ventilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF Glen Dimplex All rights reserved Material contained in this publication may not be reproduced in...