7
FRONT
üüü
(30.0 mm)
1.2 in.
(30.0 mm)
3.5 in.
(90.0 mm)
3.1 in.
(80.0 mm)
4.8 in.
(122.0 mm)
5.4 in.
(137.0 mm)
Installation
Figure 2
New Construction
1. Mark the desired location on
the floor and store the fireplace
in a safe, dry and dust free
location.
2.
Use studs to frame
an enclo-
sure with the following
mini-
mum
internal/opening dimen
-
sions (Figure 2).
!
NOTE:
An air inlet is required
for optimum mist production, see
Figure 2 for
minimum
dimen-
sions.
!
NOTE:
For optimal perfor
-
mance, the following
minimum
clearances between the instal
-
lation surface and any surface
above should be maintained:
• Cassette Only: 12 in. (305 mm)
• Cassette with Dimplex heater:
19 in. (483 mm)
Figure 3
3.
Secure unit through the two
holes in the bottom of the unit
into supports to prevent the
unit from hanging from the top
flange, see figure 3 for dimen
-
sions.
4.
The unit is equipped with a
power supply plug and a fused
receptacle (Figure 4), the plug
should be plugged
directly into
a 15 A, 120 V outlet.
CAUTION:
During operation
8.5 in.
(216mm)
6.7 in.
(170mm)
Air Inlet
DFI400: 100cm
2
DFI600: 150cm
2
Supports: 0.75 in (19 mm) high
Exit for Cord
DFI400: 15.75 in. (400mm)
DFI600: 22.05 in. (560mm)
Installation
Surface