3.2 Switch box
The switch box is located in the heat pump. It can be swung out
after removing the lower front cover and loosening the fastening
screw located in the upper left-hand corner.
The switch box contains the supply connection terminals as well
the power contactors and the soft starter unit.
The plug connector for the control line is located on the base of
the device adjacent to the cable gland in the base plate.
3.3 Heat pump manager
Use the heat pump manager included in the scope of supply to
operate the air-to-water heat pump.
The heat pump manager is a convenient electronic regulation
and control device. It controls and monitors the entire heating
system on the basis of the external temperature, including do-
mestic hot water preparation and safety systems.
The customer must install the return temperature sensor and the
external temperature sensor, which are supplied with the heat
pump manager / with these instructions together with the neces-
sary fixing accessories.
The enclosed operating instructions describe the function and
use of the heat pump manager.
4 Transport
ATTENTION!
When transporting the heat pump, ensure that it is not tilted more than
45° (in any direction).
Use a wooden pallet for transporting the heat pump to the final in-
stallation location. The basic device can be transported either
with a lift truck or a crane. The transport eyebolts must be re-
moved after crane transport and the sheet metal openings closed
with the closing plugs supplied.
After the transport, the transport securing device is to be re-
moved on either side at the bottom of the unit.
ATTENTION!
The transport securing device is to be removed prior to commissioning.
5 Set-up
5.1 General
The device should always be installed on a permanently smooth,
even and horizontal surface. The entire frame should lie directly
on the ground to ensure a good soundproof seal and to prevent
the water-bearing components from becoming too cold. If this is
not the case, additional insulation measures may be necessary.
It must be possible to carry out maintenance work without hin-
drance. This is ensured when observing the distances to solid
walls as shown in the figure.
Measurements of 0.15 and 0.4 m are to be allowed for on the
narrow sides of the heat pump (either way around) so that the
condensate tray may be cleaned.
Never install the device in rooms subject to high humidity. Con-
densation can form on the heat pump and air circuit if the humid-
ity exceeds 50% and the external temperature is below 0 °C.
Neither frost nor temperatures higher than 35 °C must occur in
the installation location at any time of the year.
If the heat pump is installed on an upper storey, the load-bearing
capacity of the ceiling should be checked. On account of the
acoustics, measures for isolating possible vibrations should also
be very carefully planned in advance as well. Installation on a
wooden floor is not recommended.
ATTENTION!
Do not restrict or block the area around the air inlet or outlet.
5.2 Condensed Water Pipe
Condensed water that forms during operation must be drained
off frost-free. To ensure proper drainage, the heat pump must be
mounted horizontally. The condensate pipe must have a mini-
mum diameter of 50 mm and must be fed into a sewer in such a
way that it is safe from frost. Do not discharge the condensate di-
rectly into clearing tanks or cesspits, as aggressive vapours or a
condensed water pipe which has not been laid in a frost-free
manner could destroy the evaporator.
5HPRYHVFUHZLQ
WUDQVSRUWORFN
P
P
P
Содержание LI 40AS
Страница 2: ......
Страница 22: ...EN 10 English 11 ...
Страница 32: ...FR 10 Français 11 ...
Страница 37: ...www dimplex de A V Anhang Appendix Annexes 3 2 3 2 Last Load Charge LI 40AS ...
Страница 38: ...A VI Anhang Appendix Annexes 3 3 3 3 Anschlussplan Circuit Diagram Schéma électrique LI 40AS ...
Страница 45: ...www dimplex de A XIII Anhang Appendix Annexes 6 ...
Страница 46: ...A XIV Anhang Appendix Annexes 6 ...
Страница 47: ...www dimplex de A XV Anhang Appendix Annexes 6 ...