Section 6: Installation considerations
When deciding the location to install the heat pump the
items contained within this chapter should be considered.
Physical location
The heat pump is for outdoor installation only. It should
also be installed in a place where:
The condensate can easily be drained away.
Hydraulic connections can easily be made to the
heating system and the DHW cylinder.
There is no risk of a flammable gas leak or any
outlets vents from any other system.
The wiring lengths come within reasonable
ranges particularly taking note of the 15m
controller cable.
Fixing of the heat pump
The heat pump should be fixed on two flat, horizontal and
solid hard surfaces such as concrete pads that are
capable of taking the unit‟s weight and draining the
condensate.
To prevent tipping, the heat pump must be suitably fixed.
The fixing should be strong enough to prevent the unit
from tipping over if the base becomes unlevel over time.
Suggested dimensions of concrete pads as shown in
Figure 7
.
A
152
B
1002
C
300
D
356
E
400
F
520
G
400
H
600
When installing the product in a place where it will be
affected by strong wind such as wind blowing between
buildings or on a rooftop an overturn prevention wire
supplied by the installer may be necessary
.
Wall mounting
If the heat pump is to be wall mounted a condensate
collection tray (supplied by the installer) should be fixed
under the heat pump. The pipe from the tray to a suitable
drain should be heated so that it can‟t freeze and become
blocked.
The installation of an air source heat pump
should be carried out by a Dimplex Accredited
installer.
Содержание LA 12 MI
Страница 35: ...Page 34 Package 1 and 2 Plumbing Schematic...
Страница 36: ......
Страница 40: ...Page 39 CE declaration of conformity...
Страница 41: ...Page 40 LA 6 MI performance...
Страница 42: ...Page 41 LA 6 MI continued...
Страница 43: ...Page 42 LA 9 MI performance...
Страница 44: ...Page 43 LA 9 MI performance continued...
Страница 45: ...Page 44 LA 12 MI performance...
Страница 46: ...Page 45 LA 12 MI performance continued...
Страница 47: ...Page 46 LA 16 MI performance...
Страница 48: ...Page 47 LA 16 MI performance continued...
Страница 49: ...Page 48 Product Dimensions LA 6 MI and LA 9 MI...
Страница 50: ...Page 49 Product Dimensions LA 12 MI and LA 16 MI...
Страница 51: ...Page 50 LA 6 MI and LA 9 MI Spare parts Note the non numbered parts are not kept as standard service parts...
Страница 56: ...Page 55 LA 12 MI and LA 16 MI Spare parts Note the non numbered parts are not kept as standard service parts...
Страница 61: ...Page 60 Information for DHW cylinder with buffer ECS125HP 580...
Страница 62: ...Page 61 Information for DHW cylinder with buffer ECS150HP 75 580...
Страница 63: ...Page 62 Information for DHW cylinder with buffer ECS210HP 75 580...