EN-8
English
11
11 Device Information
1
Type and order code
LA 11TAS
LA 16TAS
2
Design
2.1
Controller
external
external
2.2
Installation location / degree of protection according to EN 60529
Outdoor / IP24
Outdoor / IP24
2.3
Antifreeze condensate tray / heating water
Heated / yes
1
1. The heat circulating pump and the heat pump manager must always be ready for operation.
Heated / yes
1
2.4
Performance levels
1
1
3
Operating limits
3.1
Heating water flow / return
°C
up to 58 ± 2 / from 18
up to 58 ± 2 / from 18
Air (heat source)
°C
-25 to +35
-25 to +35
4
Performance data / flow rate
4.1
Heating water flow rate /
internal pressure differential
A7/W35/30
m³/h / Pa
1,9 / 10300
2,6 / 11900
A7/W45/38
m³/h / Pa
1,4 / 6000
1,9 / 7200
Minimum heating water flow
A7/W55/45
m³/h / Pa
0,9 / 3400
1,3 / 4400
4.2
Heat output / COP
2
2. These data indicate the size and capacity of the system according to EN 14511 (5K at A7) and (10K at A2) without weather-proof protective cover. For an analysis of the economic
and energy efficiency of the system, other parameters, in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into consideration. The
specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35 °C.
EN 255
EN 14511
EN 255
EN 14511
at A-7 / W35
kW / ---
7,3 / 2,9
7,2 / 2,8
10,2 / 2,8
10,0 / 2,7
at A2 / W35
kW / ---
8,6 / 3,5
8,5 / 3,4
12,1 / 3,3
11,7 / 3,2
at A7 / W35
kW / ---
10,2 / 3,9
14,6 / 3,7
at A7 / W55
kW / ---
10,1 / 2,7
14,4 / 2,7
at A10 / W35
kW / ---
11,3 / 4,6
11,3 / 4,4
16,9 / 4,0
16,6 / 3,9
4.3
Sound power level
dB(A)
60
62
4.4
Sound pressure level at a distance of 10 m
(air outlet side)
3
dB(A)
3. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C.
31
32
4.5
Air flow
m³/h
2500
4000
5
Dimensions, connections and weight
5.1
Device dimensions without connections
H x W x L mm
1340 x 852 x 1050
1550 x 852 x 1074
5.2
Device connections for heating system
Inches
R1
R1
5.3
Weight of the transportable unit(s) incl. packaging
kg
193
231
5.4
Refrigerant; total filling weight
type / kg
R404A / 2,5
R404A / 3,5
5.5
Lubricant; total filling quantity
type / litres
Polyolester (POE) / 1,5
Polyolester (POE) / 1,9
6
Electrical connection
6.1
Load voltage; fuse protection
3~/PE 400V (50Hz) / C13A
3~/PE 400V (50Hz) / C13A
6.2
Starting current with soft starter
A
15
20
6.3
Nominal power consumption A2 W35/
max. consumption
2
kW
2,6 / 4,1
4,0 / 6,4
6.4
Nominal current A2 W35 / cos
ϕ
A / ---
4,8 / 0,8
7,4 / 0,8
7
Complies with the European safety regulations
4
4. See CE declaration of conformity
4
8
Additional model features
Type of defrosting (according to need)
Reverse circulation
Reverse circulation
Содержание LA 11TAS