6.2.2  Domestic water temperature controller 

(dial) 

 

The desired domestic water temperature level can be adjusted using the selector dial (an adjustment accurate to 
within one degree is not possible).

 

 
 
 
6.2.3  'Heat pump' switch 

 

If the 'heat pump' switch is placed in position “

 “ (On), the heat pump is ready for operation. When the domestic 

water temperature inside the tank rises above the preset setpoint, the heat pump cooling function is activated until 
the desired domestic water temperature is reached. 

 

Note 

   

If the 'heat pump' switch is placed in position 

 “ (heat pump mode), it is not possible to activate the immersion 

heater (selecting the 'immersion heater' switch position will have no effect). 

 
 
 
6.2.4  'Immersion heater' switch 

 
The integrated 1.5 kW heating element can be activated by means of the 'immersion heater' switch when there is a 
demand for hot water or a preset hot water temperature level is to be reached. 
When the 'immersion heater' switch is in position " I ", the tank content is heated up to the maximum temperature 

of the immersion heater controller

 

(factory setting 65 °C). In switch position

 

‘‘

‘‘  the immersion heater is switched off.

 

 

Note 

   

If the 'immersion heater' switch is in position 

I

 "  

(heating mode), the heat pump cooling function is deactivated 

until the 'heat pump' switch is placed in position

  

 

 “. 

Note 

  Immersion heater controller 

The factory-set switch-off temperature of 65 °C can be changed by a qualified expert (see item 2.3)

 

 
 
 
 
 
 

7. 

Maintenance / Service 

 
CAUTION! 

Prior to opening the HPCDW, the unit must be disconnected from the power supply; be careful of fan that 
may still be rotating ! 
 

General

 

 

¾

¾

¾

¾

#

#

#

#

The heat pump for cooling of domestic water is nearly maintenance-free. A few days following the 
commissioning procedure, a visual check for possible leaks in the water system is to be performed once. 

¾

¾

¾

¾

#

#

#

#

No maintenance activities need to be performed on the refrigeration cycle of the heat pump. 

¾

¾

¾

¾

#

#

#

#

For cleaning the HPCDW, simply use a damp cloth and some soapy water. Caution! Do not allow water to 
come in contact with the operating controls. Prior to commencing the cleaning procedure, withdraw the mains 
plug or disconnect the unit from the power supply.

 

 

Содержание KWP 300

Страница 1: ...Installation and Operating Manual Heat Pump for Cooling of Domestic Water with Airduct Connection KWP 300 451902 67 39 FD8411...

Страница 2: ...Connection 8 6 Commissioning 8 6 1 Domestic Water Circuit 8 6 2 Operation of the Heat Pump for Cooling of Domestic Water 9 7 Maintenance Service 10 7 1 Water Circuit 10 7 2 Air Circuit 10 7 3 Sacrifi...

Страница 3: ...explosion hazard due to gases vapours or dust The operation of the unit is not permitted with empty storage tank during the construction phase In the design and construction of the HPCDW all relevant...

Страница 4: ...ted from the domestic water at a low evaporation temperature and transferred to the refrigerant The vaporous refrigerant is drawn in by an electrically driven compressor and compressed to a higher pre...

Страница 5: ...ing STL 2 3 3 Temperature controller for immersion heater TC The temperature controller for the immersion heater controls the temperature of the water for domestic use during the immersion heater mode...

Страница 6: ...d see Figure If transport in an inclined position cannot be avoided the HPCDW heat pump switch should be taken into operation one hour after it has been moved into final position at the earliest Cauti...

Страница 7: ...ently tighten the check nuts provided on the levelling feet 5 Mounting 5 1 Connection of Water Piping The nominal pipe widths of the field installed sanitary installations must be determined on the ba...

Страница 8: ...f there is a danger of the water being contaminated during operation 6 1 2 Commissioning of the domestic water system All installations at the water and air circuits as well as all electrical installa...

Страница 9: ...g panel Switch position O heat pump is OFF in switch position the heat pump is in operation Heat pump switch Temperature dial for domestic water setpoint trans mitter left stop lowest cooling temperat...

Страница 10: ...ontent is heated up to the maximum temperature of the immersion heater controller factory setting 65 C In switch position the immersion heater is switched off Note If the immersion heater switch is in...

Страница 11: ...eplaced if necessary The electrical check is to be conducted by means of a suitable ammeter without draining the water in the tank Procedure n Withdraw PE wire from tab of sacrificial anode o Connect...

Страница 12: ...he temperature of the intake air lies above the permissible limit value 45 C If the malfunction cannot be corrected based on the above questions please consult your installer or customer service 9 Dec...

Страница 13: ...mers heater 16 Insulation 3 Evaporator 10 Temperature display 4 Hot water tank 11 Filter drier 5 Immersion heater 12 Expansion valve 6 Corrosion protection anode 13 Condenser 7 Temperature controller...

Страница 14: ...ing valve 7 Diaphragm safety valve 3 Test valve to be mounted above tank edge 4 Check valve 8 Drain 5 Manometer connection Wasseranschlu nach DIN 1988 6 8 5 1 3 4 2 1 Wasserzulauf 7 8 1 Brauchwasseren...

Страница 15: ...t Verdichter Ventilator Schalter EIN AUS W rmepumpe Schalter EIN AUS El Heizung Netzstecker Klemmleiste intern B1 B3 C1 C2 E1 F1 F2 F3 K2 K3 M1 M2 S1 S2 X1 X3 Legende 2 S1 1 T B1 4 18 26 C Verdichter...

Страница 16: ...air C 20 to 45 Water temperature selectable heat pump mode C 16 to 25 Heat up time from 25 C to 65 C electr immersion heater h 9 2 Power consumption electric heating watt 1500 Average power consumpti...

Страница 17: ...17 KKW Kulmbacher Klimager te Werk GmbH Subject to technical changes Department Dimplex Fax 0 92 21 709 589 Am Goldenen Feld 18 www dimplex de D 95326 Kulmbach...

Отзывы: