background image

single-phase supply and is supplied with a hard wired, 

three (3) wire power cord.  Connection requires a supply 

wire that must consist of two wires plus ground and have a 

rating capable of handling all loads on the circuit.  
Make all relevant electrical connections within an installed 

junction box and ensure all wiring meets all local electrical 

and building codes. Where local code requires the 

disconnection of all ungrounded supply lines, a double pole 

isolating switch must be fitted to facilitate isolation.

 

 

 

WaRnInG:  

Always use a qualified and licensed 

 

  electrician for all wiring and electrical connections.   

  Improper wiring could lead to a fire hazard.

 

 

Mounting Instruction

The heater is supplied with a wall mount bracket, three 

1. 

(3) screws and wall plugs.  Other or supplemental 

hardware should be used as needed and as appropriate 

for the type of wall being mounted to.
Unlock the wall bracket (Figure 3-A) and remove from 

2. 

the device.
Position wall bracket on wall, and mark desired position 

3. 

through bracket holes.
Drill mounting holes for the wall bracket and insert the 

4. 

wall plugs.

Align the wall bracket and firmly screw it onto the wall.

5. 

Align slots in back of heater with tabs on wall mount 

6. 

bracket and hang the device on the wall mount bracket.
Pivot down the heater and push into place  

7. 

(Figure 3-B).

Ensure that when in use, the airflow is not obstructed.

 

8. 

7210020100rev00

setting, which can be used as a frost protection setting.  

Provided that the controls are set to a heating function, the 

heater will come on when the  

surrounding temperature falls  

to approximately 5˚ C (41˚ F).

Turn the thermostat knob  

(Figure 4) to the highest position  

to warm the room rapidly.  When  

the room temperature has  

reached the desired level, turn  

the thermostat knob back slowly  

until the thermostat just clicks  

off.  The heater will then maintain  

the room temperature at the chosen level.
Should your heater fail to come on when the thermostat is 

at a low setting, this may be due to the room temperature 

being higher than the thermostat setting.

60-minute timer

The EF12* model incorporates  

a 60 minute delay timer and  

thermostat.  With the timer set  

at ‘0’ the heater will operate at  

1kW (on a 240 V supply) or  

0.75kW (on a 208 V supply)  

and low fan speed under  

the control of the thermostat. 
With the Timer in operation the  

heater will output 2kW (on a 240 V supply) or 1.5kW (on a 

208 V supply) and high fan speed with thermostatic control.
Set the timer by turning the control knob clockwise until the 

required operating time is indicated opposite the mark as 

shown in Figure 5. The heater will operate at 2kW output 

(on 240 V supply) or 1.5kW (on 208 V supply) for the set 

period, after which the output will reduce to 1 kW (on 240 V 

supply) or 0.75kW (on 208 V supply). The timer setting may 

be overridden at any time by returning the knob to ‘0’.

Protection against Overheating

A thermal cutout will switch off the heater if for any reason 

it overheats. Should the cutout operate, disconnect 

heater from power supply and determine the reason for 

overheating. Resolve the reason for overheating before 

attempting to use the heater again. To reset the heater it is 

necessary to switch off the power to the heater for several 

minutes.

Faults

If the heater does not give off heat, check the following 

points:

•   Has the thermostat been set to the desired 

 

  temperature?

•   Has the overheat protection been triggered?  See 

 

  Protection Against Overheating section.

•   Is the fuse in the fuse box switched on?

If the fault cannot be corrected, please contact a specialist 

electrical service center or else your nearest after-sales 

service.  
When the power line of this device is damaged, it must be 

replaced by the manufacturer or after-sales service, or by a 

A

B

308

190

Figure 3

7

½

(190 mm)

12”

(300 mm)

Heating operation

thermostat

The EF12* model is fitted with an adjustable thermostat 

allowing the room temperature to be controlled by adjusting 

the setting accordingly.  The thermostat has a minimum 

Figure 4

Figure 5

Отзывы: