If balanced cold water supply is required a connection 

can be taken from the bottom of the inlet group. 

6.2.3  Balanced Cold Water Supply

It is also recommended to install a drain valve (not 

supplied) in the lowest point of the cold water feed to 

the water heater. This allows the water heater to be 

drained in a controlled manner should this become 

necessary. 

6.2.4  Drain Valve

6.3  Hot Water Outlet

The hot water pipework is to be directly connected to 

the hot water outlet connection on the water heater.

A thermostatic mixing valve may be required to limit 

the outlet temperature. In this case, the valve should 

be installed following the manufacturer’s instructions, 

ensuring none of the safety equipment has been 

isolated, (i.e. make sure the connection to the 

thermostatic mixing valve is taken after the safety 

equipment of the inlet group).

6.3.1  Thermostatic Mixing Valve

6.4  Discharge Pipes from  Safety 

 Devices

6.4.1  Discharge Pipe D1

The temperature and pressure relief valve must be dis-

charged directly or by way of a manifold via a short length 

of metal pipe (D1) into a tundish; and the 

discharge pipe must be installed in a continuously down-

ward direction and in a frost free environment. Water may 

drip from the discharge pipe of the 

pressure relief device and this pipe must be left open to 

the atmosphere.

The diameter of discharge pipe (D1) should not be less 

than the nominal outlet size of the safety device, e.g. tem-

perature relief valve.

6.4.2  Discharge Pipe D2

For a detailed description of the discharge pipework D2  

(see Section 5.8.1).

6.4.3 Tundish

The tundish should be vertical, located in the same space 

as  the  unvented  hot  water  storage  system  and  be  fitted 

as close as possible to, and lower than, the safety device, 

with no more than 600mm of pipe between the valve out-

let and the tundish (see Figure 2). 

Where discharge may not be apparent, e.g. in dwellings 

occupied by people with impaired vision or mobility, con-

sideration should be given to the installation of a suita-

ble safety device to warn when discharge takes place, e.g. 

electronically operated.

Note: To comply with the Water Supply (Water Fittings) 

Regulations, the tundish should incorporate a suitable air 

gap.

Note: It is important that the tundish is 

positioned away from any electrical components.

6.5  Immersion Heater

It is recommended to insulate the hot water pipework 

from the water heater to the outlets, to reduce the 

energy requirements for providing hot water. It is also 

recommended to insulate all other exposed pipework, 

such as the T&P to the tundish, the coil flow and return 

and the cold water inlet pipes.

6.3.2  Pipe Insulation

The Edel Air Source Heat Pump Water Heater comes with 

the immersion heater factory fitted and wired. The immer

-

sion heater incorporates an independent non-self resetting 

over temperature cut-out. Should this 

operate, please investigate the cause of the cut out before 

resetting (See Troubleshooting).

Cold water 

from Mains

Balanced Cold 

Water Supply

Expansion Vessel 

Connection

Cold Water Inlet

Expansion Relief 

Valve

Figure 4: Detail showing the connection of the expansion 

vessel to the inlet group

 

Where a manifold is used it should be sized to accept and 

discharge the total discharge from all the D1 

discharge pipes connected to it.

The discharge pipework from the expansion relief valve 

must be installed constantly falling to an open point of 

discharge. It is recommended to combine it with the dis-

charge of the temperature and pressure relief valve.

Note: The T&P valve is pre-sealed and if moved the seal 

will be broken, should this occur, it will need to be re-

sealed with an appropriate sealant (Dimplex part number 

R00836-1).

Installation

Note: The expansion vessel must be installed 

to the side of the expansion relief valve on 

the inlet group. To do this the blanking plug 

must be removed and the expansion vessel 

connected, as shown in Figure 4.

Figure 3: Connection of the expansion vessel

 to the inlet group

Содержание EDL200UK-630RF

Страница 1: ...Air Source Heat Pump Water Heater Installation and User Instructions RD01144 2 Important This manual must be left with user after Installation Edel RF...

Страница 2: ...ture reference Installers are required to carry out installation commissioning and ser vicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hot Water I...

Страница 3: ...Electrical Connections 11 6 9 1 1 Electricity Provider Contact 11 6 9 1 2 Connecting the PV Function 11 7 Set Up and Use 12 7 1 Commissioning 12 7 2 Using your Hot Water Heat Pump 13 7 3 Control Box 1...

Страница 4: ...and or user This appliance can be used by children aged 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given s...

Страница 5: ...installation If in any doubt please call the appropriate help desk Disregarding the instructions given in this manual in its entirety and any relevant regulations standards and codes of practice will...

Страница 6: ...must be taken when placing the water heater in a garage or outbuilding All exposed pipework must be correctly insulated to avoid frost damage The position and orientation of the water heater should b...

Страница 7: ...2 15 22 9 0 8 28 18 1 0 35 27 1 4 G3 4 22 28 9 1 0 35 18 1 4 42 27 1 7 G1 28 35 9 1 4 42 18 1 7 54 27 2 3 Dimplex recommend an annual maintenance inspection is carried out on the water heater In hard...

Страница 8: ...on vessel membrane before filling the cylinder The pre charge should be greater than or equal to 3 bar 6 2 Cold Water Inlet with Inlet Group The discharge pipe should not be connected to a soil discha...

Страница 9: ...dwellings occupied by people with impaired vision or mobility con sideration should be given to the installation of a suita ble safety device to warn when discharge takes place e g electronically oper...

Страница 10: ...2 5 25 0 External terminal X 1 51 0 51 0 Total System Calculated Pressure Drop 320m3 hr 207 7 Pa 6 7 1 Worked Example The pressure drop information provided is for 160mm semi rigid Ubbink ducting othe...

Страница 11: ...hoose load shedding level 1 the electrical back up is prevented from running If you choose load shedding level 0 both the electrical back up and the heat pump will be prevented from running see Sectio...

Страница 12: ...ischarge and check after closing that valve is not dripping 9 Open expansion relief valve to ensure proper discharge and check after closing that valve is not dripping 10 Check all shower outlets toil...

Страница 13: ...ature remains in the authorised 7 C to 35 C range Outside of this range electrical backup ensures that the domestic hot water is heated The domestic hot water temperature provided by the heat pump is...

Страница 14: ...This function can be programmed to run between 1 and 99 days and is effective as soon as the number of days has been confirmed HOLIDAYS HOLI RETURN 8 Set number of days in standby mode Enter HOLIDAY...

Страница 15: ...exisitng programme MONDAY Set Up and Use Frost PT Frost Protection Mode ECO Heat Pump Only Running CONF Heat Pump Only Running electrical back up if needed 7 10 Programming Heating time for the tank v...

Страница 16: ...al until the screen displays Inst Menu Press the Clock and Menu buttons simultaneously Keep both buttons pressed down until the screen goes blank 7 11 1 PV Mode Setting Description Unit Range Factory...

Страница 17: ...emperature reaches 43o C The heat pump will complete the remaining charge to set temperature 7 11 2 3 Minimum Temperature To C Min No To C Min 43 o c Select Mode Enter It is possible to allow the oper...

Страница 18: ...f locking for accessing the menus In the Installer menu turn the dial to Locking LOCKING LOCKING NO Select No Enter NO Locking is not activated but manual locking is possible by pressing Menu for 3 se...

Страница 19: ...ers The Counters menu shows the number of start ups from the heat pump and the electrical backup In the Installer menu turn the dial to Counters Counter No 1 Number of start ups from the heat pump Cou...

Страница 20: ...heater and the thermostat 10 The immersion heater boss can also be used for access to view the internal components of the cyl inder 11 Re commission unit see chapter 7 1 8 2 Heat Pump Any work on the...

Страница 21: ...ich would reduce the cross sectional area of the conductor 4 Ensured the conductors are tightly and securely connected to the controls or immersion heater 5 Ensured the bared conductors are correctly...

Страница 22: ...higher than the volume in the tank The time period the appliance operates is not too short 12hrs minimum if connected to piping The water temperature is not set too low Condensates are not drain ing T...

Страница 23: ...045 2 Expansion vessel fixing kit R00094 2 DN16 3 4 BSP x 1000 flex pipe R00095 1 1 2 BSP T P valve R00020 1 15 x 22 straight PE tundish R00047 1 Temp sensor 25 C 1243950 C3S PCB Controller 1244096 70...

Страница 24: ...aintained continuously at the standard set temperature if no signal or control is connected to the external control switch OVER PRESS Heat pump pressure too high No water in tank Water is too hot 75 C...

Страница 25: ...being in contact with a part which vibrates Replace expansion valve The compressor is not working and safety temperature is activated Weakness in compressor Replace compressor ERR 02 Incorrect temper...

Страница 26: ...mation 9 1 Warranty Limits Please read the following statements carefully as it affects your warranty Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pa...

Страница 27: ...d Water supply being other than cold domestic water such as rainwater or water from a well or which has particularly hostile or abnormal properties which do not comply with the national rules and curr...

Страница 28: ...28 B C D E A 152 Figure 11 Edel Air Source Water Heater Dimensions for reference only Technical Data and Product Fiche 10 Technical Data and Product Fiche Air Intake Air Discharge...

Страница 29: ...d Product Fiche Cylinder is tested in accordance with EN12897 2006 GDC Group Ltd Edel Air Source Water Heater Product Fiche Reference EDL200UK 630RF EDL270UK 630RF Load Profile Primary M L Energy Rati...

Страница 30: ...2 kW 240V Ventilation Air flow rate 320 to 400 m3 h Air temperature 7 C to 35 C Max air pipe length rigid piping 20m in total intake and rejection Condensates flow rate 0 3 L h Condensates drainage p...

Страница 31: ...31 Power Supply Green Yellow Black Blue Brown Black Blue Blue Black Sensors Black Black Black Black Blue Black Blue Brown Black Brown Communication Bus Display 1 2 Red Fan B1244454 F HPS DV...

Страница 32: ...Red Blue Blue Black Brown Blue Green Yellow Blue Black Blue Blue Red Red Blue HTS WTS HPS High Pressure Switch C25 Compressor Start Capacitor C2 Fan Capacitor C4 Valve F Fan DV Defrost Valve RE Immer...

Страница 33: ...33 Notes...

Страница 34: ...and pressure relief valve and expansion valve been fitted and discharge tested Yes No The tundish and discharge pipework have been connected and terminated to Part G of the Building Regulations Yes A...

Страница 35: ...mments Signature SERVICE 3 Date Engineer Name Company Name Telephone Number Comments Signature SERVICE 4 Date Engineer Name Company Name Telephone Number Comments Signature SERVICE 5 Date Engineer Nam...

Страница 36: ...plex reserve the right to revise products literature and guarantee terms without prior notice due to a policy of continuous improvement www KIWA co uk www HWA co uk To speak to customer services pleas...

Отзывы: