PROBLEM

CAUSE

SOLUTION

General

Circuit breaker trips or fuse 

blows when unit is turned on

Short in unit wiring.

Trace wiring in unit.

Improper circuit current rating

Additional appliances may exceed the current rating 

of the circuit breaker or fuse.  Plug unit into another 

outlet or install unit on a dedicated 15 amp circuit.

Unit turns on or off by itself

Remote control has a similar frequency 

to other remotes in the area.

Replace Remote Control.  Initialize to Remote Control 

Receiver.

Radio frequency disturbance from out-

side sources.

Replace Remote Control and Remote Control Re-

ceiver where necessary.  Initialize Remote Control and 

Receiver

Defective Remote Control Receiver

Replace Remote Control Receiver.  Initialize to Re-

mote Control.

Lights dim in room while the unit 

is on

Unit is drawing close to circuit current 

rating

Move the unit to another outlet or install unit on a dedi-

cated 15 amp circuit

Power cord gets warm

Normal Operation

The power cord may get slightly warm to the touch 

when the heater is on

Defective power cord

Replace power cord if cord gets hot to the touch.

Appearance

Fireplace does not turn on in 

Manual Mode

Improper operation

Refer to Operation Section

No incoming power from the electrical 

wall socket

Check Fuse/Breaker Panel

Defective On/Off Switch

Replace On/Off Switch

Defective Remote Switchboard

Defective Remote Switchboard

Defective Remote Control Receiver

Replace Remote Control Receiver. Initialize with Re-

mote Control.

Fireplace does not turn on in 

Remote Mode

Improper operation

Refer to Operation Section

Remote control not initialized to fireplace

Initialize the remote control

Loose wiring

Check wiring connections

Remote Control not working

Install new battery into the Remote Control.  Reinitial-

ize remote control where necessary
Replace Remote Control Receiver where necessary.  

Initialize Remote Control Receiver to Remote Control.

Defective Remote Control Receiver

Replace Remote Control Receiver.  Initialize to Re-

mote Control

Flame Frozen

Loose wiring

Check wiring connections

Defective flicker motor

Replace flicker motor

Flame not bright or flame not 

visible

Loose wiring

Check wiring connections

Defective LED light strip

Replace LED light strip

Log set dim, not glowing

Defective LED Log Driver Board

Replace LED Log Driver Board

Flame Shudder

Defective flicker motor

Replace flicker motor

TROUbLESHOOTING GUIDE

Содержание DWF36-PG

Страница 1: ...h America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 00 28 NOV 11 IMPORTANT SAFETY INFORMATION Always read this...

Страница 2: ...Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death Operation 3 Maintenance 4 Exploded Parts Diagram 5 Replacement Parts List 5...

Страница 3: ...r area Operation Figure 1 The manual controls for the electric fireplace are located on the right end of the unit A On Off Switch The On Off Switch supplies power to all fireplace functions When the s...

Страница 4: ...e removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the Partially Reflec tive Glass can be cleaned with a damp cloth The Partially Reflective Glass should be comp...

Страница 5: ...0259RP Flicker Assembly 3 5902180100RP On Off Switch 4 2800070700RP Power Cord 5 4100190100RP Remote Control Receiver 6 3000820100RP Remote Switchboard 7 3000820300RP Remote Control 8 3000370900RP LED...

Страница 6: ...6 www dimplex com Wiring Diagram...

Страница 7: ...sest Wall Bracket Supports Wall Bracket Figure 3 Figure 4 Screw Locations Exterior Cover Plate Screws Back Panel Screws Front Glass Assembly Screws Bottom Panel Screws toward the front face Carefully...

Страница 8: ...nels on the left and right sides These hold the interior Partially Reflective Glass brackets in place and may cause the Partially Reflective Glass to fall and break Lift the glass assembly off the bod...

Страница 9: ...Note Be sure that the flanges on the bottom panel are positioned on the interior of the side and back panels of the fireplace The air deflector panel located on the interior of the bottom panel will...

Страница 10: ...to the lower electrical compartment In the lower electrical compartment reconnect the LED 19 light strip to the wires on the LED driver board using the 2 orange wire nut connectors Be sure to follow t...

Страница 11: ...lid ing one side of the bottom panel in place first before the second side The fit is tight and a flat instrument such as a flat head screwdriver may be helpful to guide the second side when pushing t...

Страница 12: ...left and three 3 on the right corner peak of the bottom panel two 2 in the center of the bottom panel edge toward the front face Carefully pull the bottom panel away from the fireplace 7 and rest it...

Страница 13: ...uch Appearance Fireplace does not turn on in Manual Mode Improper operation Refer to Operation Section No incoming power from the electrical wall socket Check Fuse Breaker Panel Defective On Off Switc...

Страница 14: ...r operation Defective heater assembly Replace heater assembly Heater fan turns on but heater lacks heat Improper operation Refer to Operation Section Loose wiring Trace wiring in unit Defective heater...

Отзывы: