background image

Two Zone Wall Mounted Programmer 

(only applicable if Programmer is 

fi

 tted to DuoHeat installation)

The programmer has two modes (i) AUTO or (ii) MANUAL

(i) 

In “Auto” mode, the radiator will change between Comfort and Setback modes (as shown in the table below) depending on your 
seven day programme. To change the programme settings or temporarily over ride the programme, see the appropriate programmer 
instructions.

(ii) 

“Manual” mode will override the auto programme setting.  There are four “Manual” mode settings shown in the table below.

RX010006 - Pilot Wire, or
RX010007 - Mains Borne Signalling

H

J

Note: 

It will take 24 hours for room temperature to reach a comfortable level when resetting 
from  “Setback”, “Frost Protect”, “Off” to “Comfort”.

Everyday Operation

Once the Background level has been set (see Achieving Optimum 
Comfort Level above), this should not require any further 
adjustment.
Adjust the Comfort setting as required to suit your comfort needs 
and occupancy pattern.  For a short period of non occupancy the 
control can be lowered slightly (we recommend by no more than 2 
bars) to save energy when the room is unoccupied and increased 
again when more heat is needed.

Non Occupancy (vacant)

For long periods of non occupancy, reduce the 

Background 

 and 

the 

Comfort

 to their lowest settings.

It will take 24 hours for room temperature to reach a 
comfortable level when resetting from Low settings to Normal 
settings.

Child Lock Operation

To activate the child lock simultaneously depress the 

+

 

and 

-

 

buttons for a period of 3 seconds.  After this period the child 

lock is in operation and the LED will illuminate for short period and 
then revert to the setback setting.  The LED beside the key symbol 
will illuminate while the child lock is in operation.

Once in the locked position, if either of the controls are operated 
the LED will resume maximum illumination for a short period before 
reverting back to the setback position.

To deactivate the child lock, depress the buttons simultaneously 
again for 3 seconds and the buttons will become active.

Safety - Overheat Protection

For your safety, this appliance is 

fi

 tted with thermal cut-outs.  In the 

event that the product overheats, the cut-outs switch the radiator 
off automatically.  In the event of these safety cut-outs activating 
please inform the installer or Dimplex Customer Services for advice 
in order to reset the cut-outs.

Programmer Mode 

 

Temperature Setting 

 

 

 

DuoHeat Radiator – 

          “Temperature 

control 

display 

setting”

 

 

 

Comfort Setting (radiator setting).   Each  

 

Comfort   

 

Radiator will operate as set in  “controls”  

 

Display will remain as shown in Quick Start Guide

   section 

of 

Operating 

Instructions.

 

 

 

Setback will reduce the Comfort setting by    

Display will show two red bars less.eg. if “Comfort” 

Setback  

 

2°C, and will leave the Background   

 

displays 5, “Setback” will display 3 red bars.

   unaffected.

Frost Protect 

 

Room temperature will be maintained at  

 

Display will show one red bar.

   16°C 

with 

Background 

operating.

 

 

 

This will completely switch off radiators, 

Off 

 

 

e.g. during the summer heating may not be    

Display will show one red bar.

   required.