clockwise all the way to turn 

on the heater.  When the room 

reached the desired temperature, 

turn the thermostat knob counter 

clockwise until you hear a click.  

Leave in this position to maintain 

the room temperature at this 

setting.  For additional heat, turn 

clockwise until you hear the click 

again and the heater will turn on.

!

 NOTE:  

The heater may emit 

a slight, harmless odor when 

first used.  This odor is a 

normal condition caused by 

initial heating of internal heater 

parts and will not occur again.

Resetting the Temperature 

Cutoff Switch 

This unit is equipped with a 

thermostat which controls the 

temperature of the room.  It does 

this by turning the heater on 

and off.  The heater is protected 

with a safety device to prevent 

overheating.  should the heater 

overheat, an automatic cut out 

will turn the heater off and it will 

not come back on without being 

reset.  It can be reset by switching 

the on/off switch to off and 

waiting five (5) minutes before 

switching the unit back on.

 

CAUTION:  

If you need 

to continuously reset the 

heater, unplug the unit and 

call Dimplex north America 

Limited at 1-888-346-7539 

for technical support.  Please 

have your model and serial 

number ready when calling.

Remote Control

The fireplace is supplied with a 

radio frequency remote control.  

This remote control has a 

range of approximately 50 feet 

(15.25m).  It does not have to 

be pointed at the fireplace and 

can pass through most obstacles 

(including walls).  It is supplied 

with one of 243 independent 

frequencies to prevent 

interference with other units. The 

frequency designation is indicated 

on the back of the remote control.

Remote Control Initialization/

Reprogramming

Follow these steps for remote 

control initialization and if 

required, re-initialization:

Ensure that power is supplied 

1. 

through the main service 

panel.

open upper grille to access 

2. 

manual controls. (Figure 4)

Turn on/off switch to on 

3. 

(Figure 4A). 

  Operation

Содержание DFP6755N

Страница 1: ...ORMATION Always read this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent pe...

Страница 2: ...and techniques which if not carefully followed will result in damage to the equipment Warning Procedures and techniques which if not carefully followed will expose the user to the risk of fire seriou...

Страница 3: ...nty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace NO NEED TO RETURN TO THE STORE Q...

Страница 4: ...y unit with a damaged cord or plug or if the heater has malfunctioned or if Important Instructions the fireplace has been dropped or damaged in any manner Return heater to authorized service facility...

Страница 5: ...lug one blade is wider than the other The plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified el...

Страница 6: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Страница 7: ...inches 30 5 cm deep Figure 1 You should allow inch 0 6 cm around the fireplace insert for ease of installation This fireplace does not require any venting CAUTION Clearance for air circulation beneat...

Страница 8: ...ce NOTE 1 A 15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or...

Страница 9: ...NG Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electrical shock and injury to persons Mantel Surround Ki...

Страница 10: ...g the fireplace into a 15 3 Amp 120 Volt outlet If the cord does not reach you may use a extension cord rated for a minimum of 1875 Watts Push the fireplace into place 4 so that the trim is against th...

Страница 11: ...ht Control Turn the interior light control knob to increase or decrease the brightness of the interior light D LED Indicators Indicates the current function of the fireplace E 3 Position Switch Pressi...

Страница 12: ...without being reset It can be reset by switching the On Off Switch to Off and waiting five 5 minutes before switching the unit back on CAUTION If you need to continuously reset the heater unplug the...

Страница 13: ...e ON button located 5 on the remote control Figure 5 This will synchronize the remote control and receiver Remote Control Usage The remote control operates the fireplace levels sequentially flames onl...

Страница 14: ...set which generate the flames and embers Helpful Hints It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the numbe...

Страница 15: ...he socket while 4 screwing in the new bulb Replace the log by pushing 5 it down and in until it rests against the partially reflective glass Upper Light Bulb Requirements Quantity of two 2 clear chand...

Страница 16: ...bility or fitness for a particular purpose and the entire risk of as to the quality and performance of the products is with the purchaser and in the event of a defect the purchaser assumes the entire...

Страница 17: ...by Dimplex or its authorized service representatives or otherwise altered This limited warranty does further not apply to defects resulting from misuse abuse accident neglect incorrect installation i...

Страница 18: ...business and all labour costs Such costs shall not be the responsibility of Dimplex For surrounds mantels and trims for the period ending at midnight on the first anniversary of the date of first pur...

Страница 19: ...DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER How State and Provincial law apply This limited warr...

Страница 20: ...tor 3000240200KIT Flicker Rod Assembly 6900190400RP Power Cord 4100040200RP Strain Relief 8500260003RP Flame Speed Control Board 3000240100RP Light Control Board 3000250100RP Partially Reflective Glas...

Отзывы: