4
Remote Control Functions
(All letter references are to Figure 3)
B. Set Temperature
Press
F
button
to turn fireplace on.
Press
H
to raise thermostat.
Press
G
to lower thermostat.
Press both
H
and
G
to change °F to °C.
C. Dimmer
Press the
F
button to turn the Flame/Heat on.
Repeatedly press the
J
or
I
button to decrease or increase
the brightness of the upper lights.
D. Flame Speed
Press the
F
button to turn the Flame/Heat on.
Press the
L
button to increase the speed of the flame.
Press the
K
to decrease the speed of the flame.
E. Sleep Timer
The Sleep Timer automatically shuts off the fireplace after a
preset time (from 30 minutes to 8 hours).
Press the
F
button
to turn the fireplace on.
To set the sleep timer press the
N
button.
Set the timer from 30 minutes through 8 hours. The fireplace
will automatically turn off when the sleep timer reaches zero
(0) minutes.
The Sleep Timer can be cancelled at any time by pressing
the
M
button repeatedly until the sleep timer displays nothing.
WARNING:
Disconnect power before attempting any
maintenance or cleaning to reduce the risk of fire, electric
shock or damage to persons.
F. Flame & Heat On/Off Button
Press the
F
button to turn the Flame/Heat function on.
When
B
is higher then
A
the heat will come on. To turn the
heat off, lower the
B
so that it’s setting is lower then the
A
.
The default temperature setting is 72°F (22°C).
!
NOTE:
When using the remote control the heater runs
on a thermostat. Press the
H
or
G
buttons to adjust the
set temperature. Once the desired set temperature is
reached the heater will turn off. The heater will cycle on
and off to maintain the desired set temperature.
Figure 3 - Remote Control Functions
A. Room Temperature
B. Set Temperature
C. Dimmer
D. Flame Speed Control
E. Sleep Timer
F. Flame & Heat On/Off
G. Temperature Down
H. Temperature Up
I. Dimmer Down
J. Dimmer Up
K. Flame Speed Down
L. Flame Speed Up
M. Sleep Timer Down
N. Sleep Timer Up
K
J
L
I
B
E
A
D
G
C
N
M
H
F
Disable Heat
If desired, depending on the season, the heater on the unit
can be disabled. The unit will operate in the same fashion,
with remainder of the controls.
To Disable
- Press
M
and
H
at the same time. The
temperature setting on the remote will no longer be visible.
! NOTE:
The heat will not work in manual controls either.
To Enable
- Press
I
and
K
at the same time. The temperature
setting will now be visible again.
Child Lock
(Figure 2)
Depress tab on the battery cover on the back of the
1.
remote control and remove the battery cover (Figure 2).
Move
2.
Child Lock
tab to the right to lock the remote
control.
Move
3.
Child Lock
tab back to the left to unlock the
remote control.
Replace the battery cover.
4.
!
NOTE:
To temporarily unlock the remote control press (in
order)
G
then
H
then
I
.
When the remote control’s backlight is illuminated the
Child
Lock
is bypassed. When the backlight is off the
Child Lock
is re-activated.
Maintenance
Light Bulb Replacement
Allow at least five (5) minutes for light bulbs to cool before
touching bulbs to avoid accidental burning of skin.
Light bulbs need to be replaced when you notice a dark
section of the flame or when the clarity and detail of the log
ember bed exterior disappears. There are three (3) bulbs
under the log set, which generate the flames and embers,
and two (2) bulbs above the log that illuminate the log
exterior.
Lower Light Bulb Requirements
Quantity of three (3) clear chandelier or candelabra bulbs
with an E-12 (small) socket base, 60 Watt rating. Example:
GE 60BC or Philips 60 CTC.
Do not exceed 60 Watts per bulb.
Helpful Hints:
It is a good idea to replace all light bulbs at
one time if they are close to the end of their rated life. Group
replacement will reduce the number of times you need to
open the unit to replace light bulbs. Care must be taken
when removing the log set as the log set contains LED’s and
wires.
To access the lower light bulb area:
Remove front glass assembly.
1.
Pull the front edge of the plastic ember bed or plastic
2.
grate up and forward until the rear tab releases from the
ledge located at the bottom of the Partially Reflective
Glass (Figure 10).
!
IMPORTANT:
Only handle the log set by the ember bed.
!
NOTE:
Log set fits tightly into firebox, some force may be
necessary to remove.
Set log set in front of fireplace.
3.
Disconnect the log set LED wire harness from unit.
4.