13
DFB4047
If unit was operating prior to servicing allow at least 10 minutes for light bulbs and
heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
TO REPLACE THE CAPACITOR AND TERMINAL BLOCK
1.
Open the front control cover.
2.
Remove front glass by removing the 2 outer screws holding the class clips.
3.
Remove the log grate by removing the 4 mounting screws.
4.
Remove the log set by lifting straight up.
5.
Slide the light assembly slightly and lift out of the insert being careful not to damage any
of the wiring.
6.
Remove the terminal block cover by removing the 2 retaining screws.
7.
Disconnect the wiring from the terminal block noting their original locations.
8.
Disconnect the capacitor from the terminal block.
9.
Remove the terminal bloc from the light assembly.
10. Reassemble in the reverse order as above