Dimplex CDFI400C Скачать руководство пользователя страница 8

8  

www.dimplex.com

 Assembly

Figure 4

1. 

Carefully unpack all of the 

components from the box. 

(Figure 4)

2. 

Remove top cover by turning 

the retaining tabs on both 

ends of the water reservoir. 

(Figure 5)

3. 

Install the light bulbs by 

aligning the pins on the bulbs 

and the fixture and pressing 

down until they are fully 

inserted. (Figure 6)

4.  Install the transducer so that 

it is sitting level in the circular 

holding area in the reservoir.

5. 

Orient transducer wire so that 

it does not sit directly above 

the emitter and the wire 

passes through the slot in the 

side of the tank. (Figure 5)

6. 

Reinstall the top cover and 

ensure both retaining tabs 

have been turned so that they 

are pointing inwards.

7. 

Fill and install the Refill 

Container.

!

 NOTE:  

Normal tap water can 

be used in the Optimyst

®

 as long 

as the tap water is not considered 

to be hard water.  In the event 

your tap water is hard, you may 

use softened water or distilled 

water with 1/8 tsp of salt (0.5 

mL) added to the water reservoir.  

(The addition of additional salt 

should only be used when you 

notice that the unit is not produc

-

ing mist as expected.)

!

NOTE: 

During initial 

installation, the Refill Container 

Transducer

Rock 

Media

Removable Refill 

 

Container

Light Bulbs

Remote 

Control

Curved Tray

Housing

Media 

Tray

Logset

Содержание CDFI400C

Страница 1: ...0R02 IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to install or use the Optimyst cassette For your safety always comply with all warnings and safety instructions contai...

Страница 2: ...emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the use...

Страница 3: ...void the warranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your cassette NO NEED TO RETURN T...

Страница 4: ...ons Do not use attach ments not recommended by the manufacturer Never operate this furnishing if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or droppe...

Страница 5: ...required Always use properly grounded fused and polarized outlets When transporting or storing the unit and cord keep in a dry place free from excessive vibration and store so as to avoid damage This...

Страница 6: ...electrician or serviceman if you are in doubt as to whether the product is properly grounded Do not modify the plug provided with the product if it will not fit the outlet have a proper outlet install...

Страница 7: ...in stallation surface and any surface above should be maintained 3 Secure unit through the two holes in the bottom of the unit into supports to prevent the unit from hanging from the top flange see fi...

Страница 8: ...gh the slot in the side of the tank Figure 5 6 Reinstall the top cover and ensure both retaining tabs have been turned so that they are pointing inwards 7 Fill and install the Refill Container NOTE No...

Страница 9: ...f applicable so that the opening is not blocked Figure 6 CAUTION Do not arrange the media while the unit is running since the media and or tray may be hot 9 Make sure the On Off switch is switched to...

Страница 10: ...ed by an audible beep Although the lights turn on immediately it will take 30 seconds before the flame effect starts Press to put fire in to standby mode This will be indicated by one beep C Flame Int...

Страница 11: ...to turn fireplace on push the Standby button to turn the fire place off Battery Replacement To replace the battery 1 Slide battery cover open on the remote control Figure 8 2 Install two 1 5 Volt AAA...

Страница 12: ...mL added to the water reservoir The addi tion of additional salt should only be when you notice that the unit is not producing mist as expected 5 Screw the cap back on do not overtighten 6 Return the...

Страница 13: ...e components that contain water are cleaned with soap and water on a biweekly basis A small brush has been included to assist in cleaning difficult items areas i e the trans ducer CAUTION Do not put p...

Страница 14: ...is limited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in mate rial and workmanship...

Страница 15: ...s Such costs shall be the purchaser s responsibility What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE...

Страница 16: ...I600C 69094961BBRP Light Holder Assembly 9600610200RP Removable Refill Container with Cap 0441440100RP Cap for Refill Container 0441440300RP Top Cover Assembly 9600670100RP Water Reservoir Sump 044138...

Отзывы: