Service
The UV-C emitter must only be replaced by a qualified service/
maintenance person.
The appliance must be disconnected from the mains before any
service or maintenance is carried out.
Qualified Service/Maintenance personnel must read the service
instructions below before opening the appliance.
CAUTION:
Do not operate the air-purifier without the protective
UV-C bulb cover fitted.
WARNING:
Do not operate the UV-C emitter (lamp) outside the
appliance.
Note: The UV-C bulb contains mercury (Hg).
UV-C LAMP REPLACEMENT
1. Follow steps outlined above to remove 3 in 1 filter to obtain access to the UV-C lamp.
2. Remove the lamp cover screw with a small phillips screwdriver.
3.
Carefully remove the lamp holder and unclip the attached wire.
4. Remove lamp from holder and replace with new lamp back in the holder. Please be gentle when
removing or replacing the lamp.
5. Reattach lamp wire to adjoining connector and place lamp holder back in position. Carefully place
the lamp cover over the lamp and twist clockwise and secure with screw.
6.
Replace 3 in 1 filter, base and re fasten securely.
Note:
Do not look into the UV-C lamp when it is ON.
Note: You can obtain replacement filters and UV-C lamps at www.dimplex.co.uk
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should not be disposed of within
household waste.
Please recycle where facilities exist. Check with your Local Authority or retailer for
recycling advice in your country.