background image

1. Ensure that the cultivator is placed on a flat, 

level surface.

2.  Place  an  oil  drain  tray  under  the  cultivator 

engine.
3. Unscrew the drain cap located under the 

dipstick cap using a 10 mm wrench.
5. Wait for the oil to drain.
6. Replace and tighten the drain cap.

Dipstick cap

Drain cap

1. Make sure the device is mounted on a flat, level surface.

2. Unscrew the dipstick cap on the engine.

3. Fill the crankcase with highly refined oil using a funnel.

4. The oil level should be as shown in Fig. 

  TO ADD OIL, PROCEED AS FOLLOWS:

Oil level

Oil drain plug

Spark plug

Electrode

0,6-0,8 mm

  SPARK PLUG MAINTENANCE

Spark plug is an important part which provides correct and long work of the engine. It is important to keep 

an eye on the plug – it should not have cracks, must be installed in a right way and have no soot.

  DPARK PLUG CHECKING

Recommended for use are spark plugs F6RTC, for example NGK BPR6ES.

Follow this steps to check the spark plug (

see the pictures below

):

1. Take off the cap from the spark plug.
2. Loosen the plug with the help of candle brace.

3. Carefully check if the plug is damged. Remove if it has any damage.

4. Measure the gap – it should be within 0,6-0,8 mm.

5.  Carefully clean the spark plug with the metal brush and remove the dust before reuse of the unit.

 

Please don’t forget to measure the gap.

6. Plug in the spark plug to its place.

  INTERNAL COMBUSTION ENGINE

To ensure the greatest service life of the engine, monitor the oil level and check oil and air filters for soiling 

on a regular basis. The cooling fins must be kept clean at all times to ensure sufficient cooling of the engine.

www.ks-power.de/en   

|

    17

Содержание Konner & Sohnen 4260405363926

Страница 1: ...KS 4HP 70 GASOLINE TILLERS EN Please read this manual before use Manual...

Страница 2: ...TECHNIQUE 2 Illustrations are for reference only and may vary with the cultivator model Before operating the cultivator please carefully read the owner s manual Do not allow unauthorized people and c...

Страница 3: ...tect your hands and safety shoes do not operate the cultivator in open toe shoes BE CAREFUL The engine and exhaust pipe must be kept clean to avoid potential fire Thoroughly check them for foliage gra...

Страница 4: ...width cm 70 Tilling depth cm 27 Fuel tank volume l 1 5 Crank case volume l 0 6 Transmission case volume l 0 1 Blades psc 24 Engine start manual Drive type Belt drive worm drive Forward speed 1 0 Noise...

Страница 5: ...t to break loose 5 Immediately release the clutch lever when the cultivator is blocked by foreign objects Kill the engine remove obstacles and check the cultivator for deformation and damage Replace d...

Страница 6: ...facturer is not responsible MAINTENANCE 7 MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES Damage and losses resulting from the use of non original spare parts Corrosive damage and other consequences of in...

Страница 7: ...an eye on the plug it should not have cracks must be installed in a right way and have no soot DPARK PLUG CHECKING Recommended for use are spark plugs F6RTC for example NGK BPR6ES Follow this steps to...

Страница 8: ...To ensure proper airflow in the carburetor regular maintenance of the air filter should be conducted From time to time it is important to check for contamination 1 Loosen the clamp on the top cover o...

Страница 9: ...y or misused If the claimed malfunction cannot be diagnosed or demonstrated If proper operation of the product can be restored following cleaning from dust and dirt appropriate adjustment maintenance...

Страница 10: ...www ks power de 58 1 ANNEX 1 7 4 6 2 9 10 5 3 8 odell KS 4HP 70...

Страница 11: ...2 3 4 5 6 ANNEX www ks power de 59...

Страница 12: ......

Страница 13: ...Deutschland Hauptstr 134 51143 K ln www ks power de info dimaxgroup de Polska DIMAX International Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de 47 02...

Отзывы: