EDXtreme User Instructions
7
1.7.3 Radio Communications Reliability
Radio systems are vulnerable to interference, resulting in delays between the
dynamometer scale and remote. In some instances of interference, the display shown
on the remote may be several seconds old. This can result in a hazardous situation
when the system is used as the reference for acceptable loads in cases such as proof
loading and monitoring of binding or overload. In these applications where timely
updates are critical, a communication cable should be used to physically connect the
EDXtreme and Communicator remote (see setup of wired communications).
Alternately, the EDXtreme display can be observed directly.
United States
Canada
European Countries
WARNING: Low power radio systems should not be used in applications where
timely updates of readings are required for safety purposes.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de
la Classe A prescrites dans le Règlement sur le brouillage radioélectrique edicté par le ministère des Communications du Canada.
WARNING:
This is a Class A product. In a domestic environment, this product may cause radio interference in which the user may be
required to take adequate measures.
Agency Identification Numbers
US/FCC
CAN/IC
OUR-XBEEPRO
4214A-XBEEPRO
Содержание EDXtreme
Страница 1: ...EDXtreme Dynamometer and Crane Scale User Instructions AWT35 501242 Issue AC Optional Communicator ...
Страница 10: ...8 EDXtreme User Instructions 1 8 Declaration of Conformity EDX and Communicator II ...
Страница 11: ...EDXtreme User Instructions 9 1 9 Declaration of Conformity EDX PSU ...
Страница 12: ...10 EDXtreme User Instructions ...
Страница 34: ...32 EDXtreme User Instructions 4 1 6 Setpts Future Feature ...
Страница 63: ...EDXtreme User Instructions 61 10 6 Good Force Measurement Practice ...
Страница 67: ......