4
2,000 x 0.5 lb
1,000 x 0.2 kg
10 x 0.002 kN 1 x 0.0002 T
5,000 x 1 lb
2,000 x 0.5 kg
20 x 0.005 kN 2 x 0.0005 T
10,000 x 2 lb
5,000 x 1 kg
50 x 0.01 kN 5 x 0.001 T
20,000 x 5 lb
10,000 x 2 kg
100 x 0.02 kN 10 x 0.002 T
50,000 x 10 lb 20,000 x 5 kg
200 x 0.05 kN 20 x 0.005 T
100,000 x 20 lb 50,000 x 10 kg 500 x 0.1 kN 50 x 0.01 T
Aluminum alloy (2-, 5-, and 10,000 lb)
Stainless steel (20-, 50-, and 100,000 lb)
NEMA 4X / IP66 (sealed against dust, hosedown, and corrosive agents)
Selectable pounds, kilograms, kiloNewtons, metric tons. The selected unit of
measure is saved when the power is switched off.
0.1% of rated capacity
0.1% of rated capacity
2 times per second
Normal mode: 8 times per second
Peak hold:
60 times per second
5:1
6 LCD digits, 0.9" (22.5 mm) height
RS-232 output from dynamometer or Radio-Link remote display unit.
LB, KG, KN, TONN, PH (peak hold), BAT (low battery)
On/Off, Test, Clear/Zero, Peak hold, Function key, Units
Standard 9V battery, alkaline or lithium. The ED-2000plus has approximately
200 hours of use with the 9V alkaline battery. Battery life can be extended
with the use of a 9V lithium battery. These values represent “average” use;
mode of operation, typical period of use, battery recovery, and other variables
determine the ultimate battery life. With the optional radio link installed, the
9V battery life is approximately 36-48 hours.
-4° to 140°F (-20° to 60°C)
Traceable to the National Institute of Standards and Technology (NIST).
Calibration Certificate with each unit.
Open air range:
Up to 300 feet
Update rate:
2 times per second
RF signal output: 0 dBm in 50 at 25 C in accordance to FCC Part 15.249,
and in Canada under TRS RSS-210.
Frequency:
916.5 MHz
ED-2000plus Specifications
Capacities:
Construction:
Enclosure:
Units of measure:
Accuracy:
Repeatability:
Display update rate:
Internal update rate:
Ultimate safety factor:
Display:
Outputs:
Annunciators:
Control keys:
Power:
Operating temp:
Calibration:
Optional Radio link: