background image

 

10

 

2.3 User Interface 
 
2.3.1 Main Screen 
 

The 

Main

 screen essentially provides a list of all Powerline Ethernet devices logically connected to the computer 

where the utility is running. 

The top panel shows all local Powerline Ethernet devices found connected to the computer's NIC (Network Interface 

Card). In most cases, only one device will be seen. In situations where there are more than one device connected, 

such as a USB and also an Ethernet device, the user may click to select the one to manage through and then click 

the 

Connect

 button to its right. The status area above the button indicates that your PC is connected to that same 

device. Once connected to the chosen local device, the utility will automatically scan the   

powerline periodically for any other Powerline Ethernet devices. If no local Powerline Ethernet devices are 

discovered, the status area above the connect button will indicate that accordingly.   

Figure 3

 illustrates the presence of two local devices in the computer. 

 

 

Figure 3: Multiple Local Device Connection 

Содержание DN-15021

Страница 1: ...User s Manual DN 15021 High Speed Network Powerline Adapter...

Страница 2: ...s 6 1 7 Interface Description 6 1 8 System Requirements 6 2 Powerline Networking Utility 7 2 1 Configuration Utility Setup 7 2 1 1 Installation of the Utility 7 2 2 Windows Configuration Utility 9 2 3...

Страница 3: ...2 1 Powerline Networking Installation 1 1 Simple step to install Powerline Networking...

Страница 4: ...3 1 2 Application Block Diagram 1 2 1 Internet ADSL with one computer via power outlet 1 2 2 Online game via power outlet...

Страница 5: ...4 1 2 3 Internet ADSL and Home Networking via power outlet...

Страница 6: ...es Use the home s existing Powerline Support coexist with Powerline 85M or 14M bridges Easy to install Throughout the whole house just use your power circuit to access the Internet or PC network Ortho...

Страница 7: ...POWER ON Power on OFF Powerline off or failure 1 7 Interface Description Interface Description RJ 45 Port Connect to the Ethernet Cable Secure Button Button can auto secure and group the Powerline dev...

Страница 8: ...vista 64 utility you can easy to see it in the CD auto run screen Please use the correct utility to install otherwise it can not work properly 2 1 Configuration Utility Setup 2 1 1 Installation of th...

Страница 9: ...8 Figure 1 Install Shield Screen...

Страница 10: ...he utility icon Figure 2 shows the main screen of the configuration utility This screen shot shows a Powerline Ethernet device connected as a local device and other Powerline Ethernet devices as remot...

Страница 11: ...s a USB and also an Ethernet device the user may click to select the one to manage through and then click the Connect button to its right The status area above the button indicates that your PC is con...

Страница 12: ...e between low speed and high speed devices By default the icon is displayed with the name MAC Address column shows the device s MAC address Password column shows the user supplied device password init...

Страница 13: ...ox will appear as seen below The dialog box allows the user to enter both a device name and the password A confirmation box will appear if the password was entered correctly and if the device was foun...

Страница 14: ...werline Ethernet devices connected to the computer By default the utility automatically scans every few seconds and updates the display A typical screen after naming and supplying passwords might appe...

Страница 15: ...Plug The Privacy dialog screen allows user to make the network private by changing the network name network password of devices The user can always reset a Powerline Ethernet network to the universal...

Страница 16: ...will be on a different logical network Devices previously set up with the same logical network same network name will appear in the device list afterward selecting this option The Set All Devices but...

Страница 17: ...l data concerning software and hardware on the host computer used to communicate over Powerline Ethernet Network It shall include the following Operating System Type Version Host Network Name User Nam...

Страница 18: ...exist are shown with an in the Rate column The following remote device information is available from the diagnostics screen Adapter Alias Name Adapter MAC Address Adapter Password Adapter Last known...

Страница 19: ...screen shows the software release date Figure 9 About dialog screen 2 4 2 Preferences The lower part of the panel may display options for user preferences such as turning the auto scan feature on or o...

Страница 20: ...device is in reset process Secure button can auto secure and group the Powerline devices the follow is the scenario for secure button Two Push Button trigger state conditions Adder state for a device...

Страница 21: ...ce joining existing AVLN Possible Use Case Scenario 2 Two devices joining to form new AVLN Before this scenario begin please make sure to press each device secure button 10 sec till all LEDs re flash...

Страница 22: ...21 Possible Use Case Scenario 3 Reset...

Страница 23: ...e throughput of Powerline 200M bridge is bad Ans Please follow the steps to check the problem 1 Due to the master slave structure you need to avoid plugging two Powerline bridge in the same time so yo...

Страница 24: ...A2 2005 4 EN 55024 1998 A1 2001 A2 2003 EN 61000 4 2 1995 A1 1998 A2 2001 EN 61000 4 3 2002 A1 2002 EN 61000 4 4 2004 EN 61000 4 5 1995 A1 2001 EN 61000 4 6 1996 A1 2001 EN 61000 4 8 1993 A1 2001 EN 6...

Отзывы: