TROUBLESHOOTING 

13 

THE MONITOR FUNCTIONS ‘POWER OUT’ LIGHTS, BUT 
FOLLOWING THE TEST SENSOR SIGNALS ARE PARTIALLY 
OR TOTALLY MISSING 

 

Caused by mistaken switch off of row detection, some rows are missing 
from screen. Check again and reset row detection where necessary. (See 
SETTING ROW SKIP)

  

 

Hurt cable or connector, or defected module. 
Troubleshooting: push TEST button and note the number of last detected 
seed module. 

 
 
 
 
 
 
 
 
 
 
 

E.g. Only 8 sensors are detected of 12. The source of problem can be at the 
output side of module 8, or more probably in module 9. 

 

a., LEDs do not light from module 9 up.  

- battery leads are probably hurt 
- connector is defected between modules 8 and 9. 
- output side of module 8 or the module 9 is defected 

b., LED lights at modules 9,10,…etc. 

Power supply is in order, communication cables are hurt between 

modules 8 and 9 (or connector is defected). 
- output side of module 8 or the module 9 is defected. 

 
the easiest way to find defect in a linear system is that you disconnect and bridge 
supposed defect module: 

 

skipping module 9, connect module 8 directly to module 10 

 

skipping module 8, connect module 7 directly to module 9 

 

Push TEST to verify, replace defected module 

 

Important notice

: the monitor numbers the seed modules according to 

connection order. Consequently, if a module removed,  the numbers of 
next modules jump one back E.g. if we remove module 9, module 10 
becomes module 9, and so on… 

Last 
detected 
module 

9.

7.

8.

10.

próba

próba

probe 

probe 

3. 

4. 

5. 

6. 

Содержание DMS 08 LCD

Страница 1: ...2019 09 10 rev C DMS 08 LCD version 1 x DMS 08 LCD seeding control system for PLANTERS USER S MANUAL DIGITROLL DIGITROLL Kft www digitroll hu Tel 36 52 557 480 info digitroll hu Fax 36 52 557 482...

Страница 2: ...AFT 2 SYSTEM DRAFT Seeding control system for planters 1 8 rows with area counter DS 1000 custom designed for seeder type placed in seed tube DS 2000 custom designed for seeder type placed in coulter...

Страница 3: ...ERAL DESCRIPTION 4 MOUNTING 5 MONITOR FRONT 6 SWITCH ON 6 SYSTEM TEST 7 MENU 8 SEEDING CONTROL 9 SETTING BASIC DATA 10 TROUBLESHOOTING 12 MAINTENANCE STORAGE 15 WARRANTY PROVIDED 15 MISSING SEED TIME...

Страница 4: ...etwork easy cabling and mounting SYSTEM TEST Sensordiagnostics automatic recognition and readiness test of photosensors dusty or blockaged sensor display SEEDING CONTROL Simultaneously detected seedin...

Страница 5: ...front of a non slipping wheel The best is a freewheel which sized to give at lest 1 signal in a distance traveled between 0 2 0 99 m The speed sensor gives you information about the distance traveled...

Страница 6: ...continuously spin up in quick time SWITCH ON Following switch on appear the system test which is followed by the display of test results system test settings horn wheel LED functions modes On 12V out...

Страница 7: ...e connected to the system seed sensors speed module what is the readiness for operation of connected seed sensors operability dust level check Sends data to adjustable modules DS2000 Having the test f...

Страница 8: ...U Control of Seedong Blockage Setting Missing Seed Time Reset Hectare Settings Entry pf Distance Traveled in 100 Speed Signals Entry of Working Width 100 Speed Signal Count Setting Seed Size Language...

Страница 9: ...w will disappear from display and alarm sounds in according length During the turnings at landmarks alarm is disabled automatically Example of display at a 6 row planter Missing seed time 1 5 sec nnnn...

Страница 10: ...time interval between 0 25 2 00 seconds in 6 steps Q Reset area push button for at least 2 seconds 2 sec Q Settings return to the seeding control mode to next options Q 6 9mm change size In order to r...

Страница 11: ...SENSOR LED on the monitor Accurate measurement can be reached if speed sensor exactly aligns bolt head when starting calibration Besides signal counter on screen watch this red LED as well which show...

Страница 12: ...IGHTS OR IT BLINKS This LED indicates power supply and get off when overloaded Signs LED lights normal function LED blinks partial overload LED off total external short circuit Probe Disconnect module...

Страница 13: ...fected between modules 8 and 9 output side of module 8 or the module 9 is defected b LED lights at modules 9 10 etc Power supply is in order communication cables are hurt between modules 8 and 9 or co...

Страница 14: ...WHEN SEEDER STOPPED Seeds or seed fragments picked up accidentally by the air flow are detected by the seed sensor Sensitivity was set too high adjust higher time limit to reduce sensitivity Sensor is...

Страница 15: ...monitor to direct water do not store it under 20 C and above 40 C temperature protect it from excessive heat and dust Remove the monitor from the cabine for winter and store at a dry vapourfree place...

Страница 16: ...26 34 52 69 10 4 8 12 16 25 33 10 6 13 20 27 41 55 12 3 6 10 13 20 27 12 5 11 17 23 34 46 14 2 5 8 11 17 23 14 4 9 14 19 29 39 16 2 5 7 10 15 20 16 4 8 13 17 26 34 18 2 4 6 9 13 18 18 3 7 11 15 23 30...

Отзывы: