background image

© 2020 Digitrax, Inc. 

www.digitrax.com

55

2.0  Quick Start Guide

This Quick Start Guide will have you running a train with your UT6 in about a 

minute! You will begin this process with an existing Digitrax command station 

connected to a layout or a test track. 

Make sure that you take any analog (address 0000/non-decoder) locomotives 

off the track before you begin.  Refer to Figure 1 for the UT6 throttle layout. 

Figure 2 shows an example of the color LCD and the typical HOME screen 

information display.

1.  Power up your Digitrax Command Station as normal. 

2  Plug the UT6 throttle into a LocoNet RJ12 type jack on your Digitrax 

Command Station or layout using the LocoNet cable provided with the UT6.

3. The UT6 will beep and flash-up a start screen that includes the text 

“Welcome to UT6” and other information, and then log-on to LocoNet, then 

revert to a normal HOME screen.  The STATUS BAR will show the text “LN” 

to indicate connection via a LocoNet cable, and green “Trk” letters if the track 

power is ON.  The UT6 does not need batteries when plugged into LocoNet

4.  Press the; loco 

 key, then the   key and then the 

 key again.

5. The throttle display will now show address 0000 in big numbers mid-screen, 

and a green arrow symbol showing direction, and a current speed indication 

above this.  The scrolling HELP prompt line at the bottom of the display pro-

vides useful operating hints and information in context as you use the UT6, or 

if you get confused as to control actions possible.

6. Press the power 

 key, and above key   will show Trk_ON and Trk_OFF 

above the   key indicating the soft key action that will happen 

when

 you press 

that key down. Press   and check the track status led on the command station 

is lit, indicating the track is now powered ON.

7.  Twist the throttle knob right or left, and the speed % indication above 

the direction arrow will change, and the track status led should change color 

slightly. Flip the direction change switch to reverse the direction of the Analog 

locomotive selected as address 0000.  The direction icon in the LCD shows the 

current 

system

 direction, and if this does not match the toggle switch, simply 

swap the toggle switch to correct this.

8.  With these simple steps you have made your first locomotive address selec

-

tion with your UT6 family throttle. Place an analog loco on the tracks to now 

operate it on address 0000.

ENJOY running your trains! 

Put a locomotive on the tracks that has a known decoder address, simply restart 

at step 4 above, and enter the known decoder address numbers to operate that 

locomotive.  Note that the soft key meanings will change as the screens and 

Содержание UT6 Series

Страница 1: ...helpdesk digitrax com www digitrax com Digitrax Manuals Instructions are updated periodically Please visit www digitrax com for the latest version of all manuals for available firmware updates Digitra...

Страница 2: ...tep settings 12 4 8 Multiple Unit MU or Consist operations 12 4 9 Adding a Locomotive to an MU 13 4 10 Removing a Locomotive from an MU 14 4 11 MU of mismatched locomotives 14 4 12 Controlling functio...

Страница 3: ...and connected to a compatible Digitrax USB device The UT6 functions and screens may change with updates from the Digitrax Web site so be sure to check the UT6 product pages to get the latest informati...

Страница 4: ...Key Switch Key Color LCD screen Throttle knob Forward Brake Reverse switch Figure 1 UT6 family controls and LCD screen view Heartbeat LED 0002 F sp 50 Fn0 0 1 2 3 4 5 6 7 8 9 DigiT30 12 Trk Press loco...

Страница 5: ...en arrow symbol showing direction and a current speed indication above this The scrolling HELP prompt line at the bottom of the display pro vides useful operating hints and information in context as y...

Страница 6: ...lor LCD screen The screen provides a variety of information and input prompts to assist in running locomotives and system setup This section outlines the Home Operations Screen other menu displays wil...

Страница 7: ...on is shown if the throttle is unplugged and the IR or Duplex modes are enabled with LocoNet support found The battery sym bol shows approximate battery power when the throttle is unplugged 3 The Func...

Страница 8: ...ls to get through the white LED will flash and if layout Duplex support fails the NetName will change to red text 3 1 Recharging a Digitrax BP600MH Battery pack 1 Remove the 3 AA batteries from the UT...

Страница 9: ...number will provide you addition al information about the loco address num ber you are selecting If it says free the locomotive is available for selection If it says busy the locomotive is in use on...

Страница 10: ...key pressed the key is now a soft key showing address Recall choice Press this key to bring up the non volatile list of the last 6 unique addresses used on this UT6 When in Recall Session Loco List s...

Страница 11: ...ired by another throttle Only one address at a time can be marked as a dispatched address in the system To dispatch a locomotive address using the UT6 1 Press the key to enter address selection enter...

Страница 12: ...lection and speed step setting change Once this change is made the Digitrax command station will send DCC commands to the edited decoder in the speed step setting you entered 4 8 Multiple Unit MU or C...

Страница 13: ...o use to control the MU This will be the TOP address To do this press enter the address numbers press again 3 Press again to re enter loco selection mode and the large TOP address numbers in the Loco...

Страница 14: ...MU have performance characteristics that are closely matched you can run all the MU ed locomotives in e g 128 step mode If the units are completely mismatched for example if you are running two diffe...

Страница 15: ...operate functions F0 F9 on your locomotive Select the loco you want to control Press the key until you see Fn0 at the left of the Function line This group means numeric 0 9 keys now control functions...

Страница 16: ...There is no F29 DCC function 5 4 Troubleshooting Function Operation If the function you want to operate does not respond check the following 1 Is Track Status Power on If not press the Power Back Key...

Страница 17: ...switch address selection and not function control 7 0 Expanded Menu Features To reduce display clutter the UT6 places expanded menu choices in a menu system accessed by the or MENU key Pressing the ke...

Страница 18: ...ets the time at the lower ID16 level before the display turns OFF for maximum power save and battery life Higher numbers increase LCD brightness and delays Option ID8 Enc LCD wake and ID9 FnKey LCD wa...

Страница 19: ...on a powered layout immediately Press the key then the key to turn OFF track power to the whole layout This option will stop everything on the layout without knowing what locomo tive is on which thro...

Страница 20: ...Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help OEM RF28 Manufacturer Respons...

Страница 21: ...nty before continuing onto this section Digitrax gives a one year no worries warranty against manufacturing defects and accidental customer damage on all Digitrax products That s it Simple straightfor...

Страница 22: ...2020 Digitrax Inc www digitrax com 22 22 This page left intentionally blank...

Страница 23: ...2020 Digitrax Inc www digitrax com 23 23 This page left intentionally blank...

Страница 24: ...in a particular locomotive Digitrax CV Calculators www digitrax com support cv Calculate a CV value to program your locomotive Digitrax Tool Box App www digitrax com toolbox Download our Mobile App f...

Отзывы: