Digitrax SE74 Скачать руководство пользователя страница 8

© 2022 Digitrax, Inc.

www.digitrax.com

— 8 —

problems.

9. 

Note that the example 1st SE74 SN#3122 and 2nd SE74 SN#2399 sit 

between the minimum SW 5 and maximum SW15 Base SW#'s to have no 

overlaps with the first and second SE74's.  This Switch 'gap' is because the 1st 

SE74 only uses to Sw004, but its aspect number goes from head 1 to 16, so 

any following SE74 has to have a Base Sw at 17 or above.  The DS74's don't 

use Aspect address ranges so can be arranged in this 'gap'.

10. 

Press "X" to exit any DT602 advanced mode. 

11. 

This advanced DT602 capability allows you to setup all DS7x family device 

combinations, like the SE74, DS78V, PM74 and SE74 etc, at installed posi

-

tions on a LocoNet layout, quickly and conveniently, even if all devices are 

initially at factory-default Base address SW1.

12.  If you are using other types of non-DS7x family control devices, you will 

have to note their active Base SW addresses/ranges and manually ensure the 

SE74's are configured to not overlap these.

6.1 Reading and Editing a SE74's routes:  

As for section 2.0, if 

you have a suitable DT602 plugged into LocoNet, press the; Menu>3>4 keys to 

enter Route Editor menu.  If 

any

 SE74 is on LocoNet, the DT602 will beep after 

about one second and show "DS7x" routes at the D soft key position. 

1. 

Press the D soft key to now enter the 

"Selecting DS7x device:" screen,

2.  Rotate the LH encoder knob to under

-

line the SE74 to edit routes for.

3.  Now press DOWN the LH encoder knob 

to read in and display the Routes of the 

selected SE74, as shown in adjacent 

"EDIT DS7X Rt#:" screen.

4. 

The LH encoder knob now selects a 

Route# and the RH encoder selects the 

black outlined

 Entry# to edit.  Soft A key 

will toggle the entry from T to C direc

-

tion choice. Numeric keys will change 

the SW# in the outlined Entry position. 

"Add" soft key allows inserting another 

entry at current position and "Delete" 

will remove the current entry. The "SW 

test" soft key will send just the outlined 

switch# and direction to LocoNet.

5. 

After edit of any Route is complete 

be sure

 to press the "Save" soft key  to 

update this SE74 Route to non-volatile memory.  Press "X" to exit.

6.  With LocoNet connected SE74 routes have System wide control capability.

EDIT DS7x Rt#   

01  of 8

 

Entry# TOP of 8

0100

c

0224

t

Thrown

Add

Save

Delete

DS7X Edit: LH knob selects

SW test

CS Rt

SE74  

04  #0945

Содержание SE74

Страница 1: ...y wink OFF every 2 secs as a product heartbeat showing the SE74 is operational Alternatively power from DCC feeder wires to the TKA B terminals 3 Plug in an active LocoNet to a SE74 RJ12 connector The...

Страница 2: ...om SW257 on that control heads 1 16 consecutively with 2SW per head Each SE74 uses 36 total consecutive SW addresses 2 The SW257 264 settings control heads 1 A1 Main 2 A2 Dwarf 3 Main B DC in Complete...

Страница 3: ...74 turnouts can be Broadcast setup by turnout1 SW2041 through turn out4 SW2044 10 SW1024 C turns ON Aspect Exercise cycles SW1024 T turns OFF A double click of the ID button will toggle Exercise ON OF...

Страница 4: ...e ID and OPSW LEDs will blink alternately to show one Route can be set up Release the RTS button 2 Select a switch address on your throttle between 1 and 8 and issue the command direction for Closed T...

Страница 5: ...in BOLD 5 OPSW s not in this table are reserved and should be kept at Factory default T settings for predictable operation 6 OPSW40 C will reset to Factory defaults on OPSW mode exit Table 1 SE74 OPSW...

Страница 6: ...nnected to LocoNet this will occur as a SW message to make the change and notify the system it has occurred Wire to momen tary press on buttons for SW control 2 The pins SENS1 SENS2 SENS3 and SENS4 wi...

Страница 7: ...means the 2nd SE74 SW aspect Base would need to be 17 or higher 5 Use the LH encoder knob to scroll up and down through the detected SE74 devices with an underline shown at the 2nd SE74 6 At the 2nd...

Страница 8: ...suitable DT602 plugged into LocoNet press the Menu 3 4 keys to enter Route Editor menu If any SE74 is on LocoNet the DT602 will beep after about one second and show DS7x routes at the D soft key posit...

Страница 9: ...e CV s ac tually each control 8 individual OPSW bits OPSW1 is ls bit of CV11 through OPSW8 as ms bit of CV11 5 The DT602 does not indicate to the SE74 when programming is complete After finishing CV c...

Страница 10: ...n for wiring detail and are not installed on the PCB test mast 4 The 3 wire Searchlights of Figures 6 and 7 are common cathode version and allow Lunar lamps to be connected for all 4 heads on an SE1 c...

Страница 11: ...features available 4 For 2 wire pulse solenoids e g a Kato N crossover just wire to R G termi nals in the polarity that operates as you need Do not run more than one solenoid device per SE74 pulsed R...

Страница 12: ...ty to operate under and be in compliance with CFR 47 rules as administered by the Federal Communication Commission Digitrax believes any conscientiously installed equipment following guidelines in thi...

Отзывы: