Digitrax SE74 Скачать руководство пользователя страница 7

© 2022 Digitrax, Inc.

www.digitrax.com

— 7 —

7.  For OPSW11 =C: SW1 line ON starts Route1 and SENS1 starts Route2, in 

order through SENS4 line that starts Route 8.  An empty route is ignored.

6.0 Detecting all SE74's and setting Base addresses:  

As for 

section 2.0, on a DT602 

plugged into

 LocoNet, press the; Menu>3>4 keys to en

-

ter the Route Editor menu.  If 

any

 SE74 is plugged into LocoNet, the DT602 will 

beep after about one second and show "DS7x" routes at the D soft key position. 

1. 

Press the D soft key to get the "Selecting 

DS7X device:" screen as shown beside.  

This 

example

 DT602 screen shows three 

SE74 and three SE74 devices detected on 

LocoNet, with their; Base SW address, 

active SW address count# and unique 

device serial numbers (SN or SerNo).

2.  The lowest SE74 Base address 

detected 

and sorted

  is SW0001, with 4 turnouts 

using 4 SW#'s and SN 9122. The Base 

Sw# text is displayed in RED to indicate 

an overlap/conflict with some following 

Series7 device.  

3.  This 1st SE74 shows a RED A character 

before the #SN.  This A flags this SE74 

is configured by its OPSW5=C for head 

control by DCC Aspect, so only uses 4 

SW addresses total (for turnouts only).  

4. 

The RED capitalized A indicates the detected overlap is NOT a SW# but a 

DCC Aspect head# problem with a following SE74

.  The 2nd SE74 SN0945 

is at SW/Aspect Base address 16.    To clear the 1st SE74 SW1+16(heads) 

or aspect 17  means the 2nd SE74 SW/aspect Base would need to be 17 or 

higher. 

5.  Use the LH encoder knob to scroll up and down through the detected SE74 

devices, with an underline shown at the 2nd SE74.

6.  At the 2nd SE74 underlined as shown, press the number keys 1 then 7 and 

then "Chng adr" keys.  The 1st SE74 will now change its Base SW0001 text 

to GREEN, and the large RED A will become a small GREEN a.  This means 

that we do not have an 

aspect overlap

 problem with the 2nd SE74 now at 

Base adr SW0017.  The GREEN 'a' character flags that this 1st SE74 is in 

ASPECT control mode to control all its signal heads.

7.  The 3rd SE73 SN#0745 is RED showing it has a problem with a following 

Series7 device.  Here the RED large S shows it has a SW address overlap with 

the 3rd SE74 #2399 at its base address of Sw0075. .  The 3rd SE74 shows its 

SW Out# range as 36 (4+32) because it is NOT in aspect control mode, so 

the following device SW base address must be 

at or above 

Sw40+36 = Sw76.

8. 

Use the LH encoder knob to select this 3rd SE74, then press 7, 6 then "Chng 

adr" keys, and the 3rd SE74 data turns green with no problems found.  The 

full display page overlaps are not completely sorted and re-evaluated until 

the "Chng adr" soft key A is pressed.  Best practice is to scroll past a 10th 

device line to see if Series7 devices above the current display page of 10 have 

CsRt 

Selecting DS7x device

Device:    Base+Out#         SerNo

SE74   

04  A #9122

DS74   

04     #3122

DS74   

04     #2399

SE74

 

  

04  a #0945

SE74

   

36  S #0745

DS74   

04     #2399

DS7x device select: LH knob

 

Chng adr

Ident

Содержание SE74

Страница 1: ...y wink OFF every 2 secs as a product heartbeat showing the SE74 is operational Alternatively power from DCC feeder wires to the TKA B terminals 3 Plug in an active LocoNet to a SE74 RJ12 connector The...

Страница 2: ...om SW257 on that control heads 1 16 consecutively with 2SW per head Each SE74 uses 36 total consecutive SW addresses 2 The SW257 264 settings control heads 1 A1 Main 2 A2 Dwarf 3 Main B DC in Complete...

Страница 3: ...74 turnouts can be Broadcast setup by turnout1 SW2041 through turn out4 SW2044 10 SW1024 C turns ON Aspect Exercise cycles SW1024 T turns OFF A double click of the ID button will toggle Exercise ON OF...

Страница 4: ...e ID and OPSW LEDs will blink alternately to show one Route can be set up Release the RTS button 2 Select a switch address on your throttle between 1 and 8 and issue the command direction for Closed T...

Страница 5: ...in BOLD 5 OPSW s not in this table are reserved and should be kept at Factory default T settings for predictable operation 6 OPSW40 C will reset to Factory defaults on OPSW mode exit Table 1 SE74 OPSW...

Страница 6: ...nnected to LocoNet this will occur as a SW message to make the change and notify the system it has occurred Wire to momen tary press on buttons for SW control 2 The pins SENS1 SENS2 SENS3 and SENS4 wi...

Страница 7: ...means the 2nd SE74 SW aspect Base would need to be 17 or higher 5 Use the LH encoder knob to scroll up and down through the detected SE74 devices with an underline shown at the 2nd SE74 6 At the 2nd...

Страница 8: ...suitable DT602 plugged into LocoNet press the Menu 3 4 keys to enter Route Editor menu If any SE74 is on LocoNet the DT602 will beep after about one second and show DS7x routes at the D soft key posit...

Страница 9: ...e CV s ac tually each control 8 individual OPSW bits OPSW1 is ls bit of CV11 through OPSW8 as ms bit of CV11 5 The DT602 does not indicate to the SE74 when programming is complete After finishing CV c...

Страница 10: ...n for wiring detail and are not installed on the PCB test mast 4 The 3 wire Searchlights of Figures 6 and 7 are common cathode version and allow Lunar lamps to be connected for all 4 heads on an SE1 c...

Страница 11: ...features available 4 For 2 wire pulse solenoids e g a Kato N crossover just wire to R G termi nals in the polarity that operates as you need Do not run more than one solenoid device per SE74 pulsed R...

Страница 12: ...ty to operate under and be in compliance with CFR 47 rules as administered by the Federal Communication Commission Digitrax believes any conscientiously installed equipment following guidelines in thi...

Отзывы: