background image

Transmitter and locator must be

Paired

and on the same band before

data will display. For DigiTrak remote displays, see the DCI DigiGuide
App.

Locate Mode Screen Shortcuts

• Toggle down to return to the Main Menu.

• Toggle up to set and enter Target Steering.

• Toggle right and hold to switch between up and down locator bands

and view calibration settings.

• Hold the trigger for depth readings.

For more information on these features, see the

DCI DigiGuide App

.

Basic Locating

1.

Find the Front Locate Point (FLP) and Rear Locate Point (RLP) by
centering the target ball in the box. Mark the positions.

2.

At the FLP, hold trigger for predicted depth reading. The Reference
indicator

R

icon will appear. The Locate Line (LL) may not appear if

this step is skipped.

3.

Find the LL by centering the line in the box between the FLP and RLP
(see Locate Mode screen on next page).

4.

View depth by holding the trigger at the LL on the line between the
FLP and RLP.

5.

To improve depth/data readings, hold the trigger five or more seconds
to enable Max Mode. See the

DCI DigiGuide App

for more information.

Changing Transmitter Frequency Band

Switch between Up and Down bands during pre-bore calibration or mid-
bore to overcome interference. See page 6 to change bands on the locator.

Above Ground – Power-On Method

Insert transmitter (Tx) batteries and battery cap with the Tx pointing
down (battery compartment on top) to power on in the Down band. Insert
batteries with the Tx pointing up to power on in the Up band.

Above Ground – Tilt Method (In or out of drill head)

Hold the Tx at the same (±2) general clock position (CP) for
this whole procedure. Hold Tx powered on at level (0±10°)
for at least five secs. Tilt Tx up at approx. +65° (almost
vertical) for 10–18 secs., then return to level for 10–18 secs.
When the Tx changes bands, data disappears from the
locator.

- 5 -

Содержание Falcon F2+

Страница 1: ... Optimization Tx FO Toggle to menu options and click trigger to select Toggle down to find Power Off Steps Required Before Drilling 1 Scan and Pick Optimized Bands There are two methods to pick frequency bands Quick Scan Pair and Scan Pick and Pair To decide which method to use visually inspect entire site for sources of interference such as traffic loops and other utilities Pay attention to the d...

Страница 2: ...umbers 5 Quick Select Up and Down bands 6 Up band Quick Select option 7 Down band Quick Select option 8 Rescan 9 Pair 10 Exit FO Results c It is important to return to the point on the drill path with the highest noise Rescan to optimize the bands The lowest noise bands are marked with up and down arrows d You can do one of the following To continue using the currently selected bands the two on th...

Страница 3: ...pt calibration menu opens 3 Calibrate the Up Band Calibrate in an interference free environment after any pairing band change or Tx Power Mode change If you change both bands the locator and Tx calibrates the Up band first a Place the Tx in a housing on level ground and measure 3 m from the nearest edge of the locator to the center of the drill head b Click Continue to calibrate Do NOT move the lo...

Страница 4: ... Menu Use the Settings menu to set the depth units pitch units telemetry channel roll offset temperature units and LOC security settings Set the remote display to match locator settings Height Above Ground HAG Menu Height Above Ground HAG is the distance from the ground to the bottom of the locator while it is held or on a TrakStand Enabling HAG on the Main menu lets you take accurate below ground...

Страница 5: ... and RLP see Locate Mode screen on next page 4 View depth by holding the trigger at the LL on the line between the FLP and RLP 5 To improve depth data readings hold the trigger five or more seconds to enable Max Mode See the DCI DigiGuide App for more information Changing Transmitter Frequency Band Switch between Up and Down bands during pre bore calibration or mid bore to overcome interference Se...

Страница 6: ...ta will begin displaying as transmission resumes in the new band For detailed information install the DCI DigiGuide App from your smart device s App store or download the Operator s Manuals from digital control com Printed manuals are available upon request If you have questions contact your regional DCI office or Customer Service at 1 425 251 0559 or 1 800 288 3610 US CA Watch our DigiTrak traini...

Страница 7: ...al and you can ignore the A warning Transmitter Signal Field Geometry Level Transmitter 1 Side view 2 RLP Rear Locate Point 3 LL Locate Line 4 FLP Front Locate Point Pitched Transmitter 1 Bird s eye view top down 2 Drill rig 3 Side view underground 4 RLP Rear Locate Point 5 LL Locate Line 6 Transmitter Tx 7 Bore path 8 FLP Front Locate Point FLP and RLP are not equidistant from the LL when the tra...

Страница 8: ...gger held at LL 1 HAG on 2 Tx depth Depth Screen Line in the Box at LL Trigger held at FLP 1 HAG off 2 Pitch 3 Predicted depth of Tx 4 Tx battery strength 5 Horizontal distance between Tx and FLP Only valid at FLP Invalid at RLP Predicted Depth Screen Ball in the Box at FLP only The predicted depth is the depth the transmitter is calculated to be when it reaches the Front Locate Point FLP if it co...

Отзывы: