![DigitaLinx DL-RMKTC2H-2 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/digitalinx/dl-rmktc2h-2/dl-rmktc2h-2_installation-manual_2500401012.webp)
Command Tab (RS232 Display Control)
This tab defines the RS232 display control commands. If a display requires hex commands, make sure
the
Hex
box is checked.
Display On / Display Off
Enter the RS232 command to turn ON or OFF the display.
Input Select
Enter the RS232 command to switch to the display or projector input which is connected to the DL-
RMKTC2H-W Receiver.
Input Select Delay
Enter the delay time in seconds between the
Display ON
and
Input Select
commands. This delay may be
between 1 and 100 seconds. The default time is 5 seconds.
Baud Rate
Select the baud rate necessary to communicate with the display. Available baud rates are: 2400, 4800,
9600, 14400, 19200, 38400, 56000, 57600, and 115200 baud.
Parity
Select the parity bit setting for your RS232 strings. Available parity settings are NULL, ODD or EVEN.
No Activity Timeout
Set the
No Activity Timeout
as needed in hours and minutes, the system will enter standby mode and
the display will automatically shutdown when no input video signal is detected after the specified
timeout.
Save/Cancel
Saves or cancels changes made to this screen.