background image

Included Accessories

Safety Precautions

• 

DL-RMKTC1H1V-W Control Keypad, Transmitter and Receiver Set

• 

Locking Power Supply with US Power Cable

• 

USB Type A to Type B Cable

• 

IR Emitter

• 

Two Mounting Rails with Screws

• 

Six Wall Box Screws

• 

Three 3-pole Removable Terminal Blocks

• 

One 2-pole Removable Terminal Block

• 

One 4-pole Removable Terminal Block

• 

Installation Guide

To insure the best from the product, please read all instructions carefully before using the 

device. Save this manual for further reference.

• 

Unpack  the  equipment  carefully  and  save  the  original  box  and  packing  material  for 

possible future shipment.

• 

Follow basic safety precautions to reduce the risk of fire, electrical shock and injury to 

persons.

• 

Do not dismantle the housing or modify the module. It may result in electrical shock or 

burn.

• 

Using  supplies  or  parts  not  meeting  the  products’  specifications  may  cause  damage, 

deterioration or malfunction.

• 

Refer all servicing to qualified service personnel.

• 

To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this 

product near water.

• 

Do not put any heavy items on the extension cable in case of extrusion.

• 

Do not remove the housing of the device as opening or removing housing may expose you 

to dangerous voltage or other hazards.

• 

Install the device in a place with good ventilation to avoid damage caused by overheating.

• 

Keep the module away from liquids.

• 

Spillage into the housing may result in fire, electrical shock, or equipment damage. If an 

object or liquid falls or spills on to the housing, unplug the module immediately.

• 

Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the 

device before cleaning.

• 

Unplug the power cord when left unused for a long period of time.

• 

Information on disposal for scrapped devices: do not burn or mix with general household 

waste. Please treat them as normal electrical waste and recycle the devices properly.

Содержание DL-RMKTC1H1V-W

Страница 1: ...the wall plate transmitter and the receiver The wall plate control module connects to the wall plate transmitter with a second Category 6 cable All the power needed for the system is provided by the r...

Страница 2: ...fications may cause damage deterioration or malfunction Refer all servicing to qualified service personnel To prevent fire or shock hazard do not expose the unit to rain moisture or install this produ...

Страница 3: ...oC TCP IP A B C D E F G H I J K L 1 Firmware Update Port 2 System Power Indicator 3 HDBaseT Link Indicator 4 HDCP Status Indicator 5 Receiver Power Indicator A Network Port B HDBaseT Input and PoC Out...

Страница 4: ...DBT OUT POWER RS232 DL RMKTC1H1V W TX Transmitter 1 Power Indicator and Source Select Button 2 Link and HDCP Status LEDs and Reset Button 3 VGA Audio Input with Activity Indicator 4 USB Port to Host P...

Страница 5: ...DL RMKTC1H1V W PAD Control Pad A B 1 Mic Source Indicator 2 System Display On Button 3 HDMI Input Select Button 4 IR Receiver 5 Multifunction Volume Control with Volume Level Indicator 6 System Displ...

Страница 6: ...KTC1H1V W receiver Connect the display TX signal to Rx on the DL RMKTC1H1V W extender To ensure proper performance of the DL RMKTC1H1V W it is recommended that you use solid core Category 6 F UTP cabl...

Страница 7: ...Speaker Wiring Configurations 4 Load with 4 Speakers 4 4 4 Load with 8 Speakers 8 8 8 8...

Страница 8: ...to the IR receiver port of the display 9 If the display is to be controlled via RS232 plug the 3 pole terminal plug end of the included RS232 cable into the RS232 port on the Receiver and the DE9 end...

Страница 9: ...MKTC1H1V W is 192 168 0 178 This can be changed in the Network settings To change the settings of the web browser interface or program RS232 commands for the display log into the DL RMKTC1H1V W as an...

Страница 10: ...e display on or off System Turn the system on or off Volume Mute and unmute audio sources Volume may be changed by pressing the or buttons or by dragging the volume slider To enter the configuration s...

Страница 11: ...lled via RS232 I O Mode Select Select whether the contact closures need to be normally open N O or normally closed N C to mute the audio output for integration with a mass notification system Floor As...

Страница 12: ...time in seconds between the Display ON and Input Select commands This delay may be between 1 and 100 seconds The default time is 5 seconds Baud Rate Select the baud rate necessary to communicate with...

Страница 13: ...ration Tab This tab defines the scaled output resolution for the DL RMKTC1H1V W Choose a resolution setting compatible with the connected display Output will scale automatically once selection has bee...

Страница 14: ...CP IP Address Enter the IP address for the system Subnet Mask Enter the subnet mask for the system Gateway Enter the gateway address for the system Save Cancel Saves or cancels changes made to this sc...

Страница 15: ...or can be programmed so system power and display power can be controlled separately By default the DL RMKTC1H1V W is set to control the connected display by IR The adjustment in the web GUI for this...

Страница 16: ...isplay remote at the Control Panel IR sensor and the press the Power On button on the remote The ON button on the Control Panel will stop flashing 3 Press the OFF button and it will start to flash 4 P...

Страница 17: ...W system can be configured to synchronize with the power of the display simultaneously or can be programmed so system power and display power can be controlled separately After the RS232 settings are...

Страница 18: ...he connected displays RS232 ON or OFF command sets into the DL RMKTC1H1V W navigate to the COMMAND page and enter in the command sets and proper RS232 settings according to the display manufacturers s...

Страница 19: ...e Volume knob clockwise will raise the volume counterclockwise will lower the volume Pressing the Volume knob will mute or unmute the current audio source Pressing and holding the Volume knob for thre...

Страница 20: ...s an alternative method to control the system without having to interact with the Control Panel The default IP address of the DL RMKTC1H1V W is 192 168 0 178 This can be changed in the Network setting...

Страница 21: ...VGA Switch between HDMI and VGA inputs Display Turn the display on or off System Turn the system on or off Volume Mute and unmute audio sources Volume may be changed by pressing the or buttons or by...

Страница 22: ...e Control Panel for three seconds As soon as the buttons are released they will light up while the upload is in progress Remove the thumb drive from the Configuration port once the buttons go dark FCC...

Страница 23: ...up to 190Mbps Contact Closure NO and NC for system mute HDBaseT Signal Characteristics Maximum Distance 30 m 98 ft Cable Requirements Continuous solid core Category 6 or greater with TIA EIA 568B cri...

Страница 24: ...CO 80921 Toll Free 800 530 8998 Fax 719 260 0075 www libav com Digitalinx is a brand of Liberty AV Solutions Thank you for your purchase For Technical Support please call our toll free number at 800...