The VMAXD1 supports RAID 1 and RAID 5 (Up to 8 Terabytes).
Configuring RAID
£
Prepare the hard drives and connect to the VMAXD1.
RAID 1 requires more than 2 HDDs. RAID 5 requires more than 5 HDDs.
¤
Turn VMAXD1 ON. Right click VMAXD1 and go to
[Setup] > [Disk Config] > [New]
.
¥
Select the HDD and click
[RAID 1 Creation]
.
For RAID 5, select
[Raid 5 Creation]
.
¦
Press OK to initialize RAID.
§
When completed, RAID will move to Recording tab.
¨
To check the configured RAID information, go to Recording tab. Then, select the RAID and click RAID Info.
Resync
This will occur when synchronization is broken by unexpected power failure. During this process, resolution would be restricted to CIF at
120fps.
Recovery
The VMAXD1 will synchronize again when RAID configuration has been changed. For example when a different HDD is configured, when
a different HDD is detected, and/or when a redundant HDD is changed.