3. Other
control
Function
Command
Description
Acknowledge (if enabled)
Select RS-232
acknowledge
0xc1, “0” | “1”
Disable/enable command
acknowledge.
“0” – acknowledge disabled.
“1” – acknowledge enabled.
Auto-setup
#
0xc3
Start auto-setup of current
vmode.
“0” – fail.
“1” – successful.
Command
availability
0xc4, n
Check whether a command is
available.
“0” – not available.
“1” – available.
Auto-calibration
#
0xc5
Start auto-calibration of gain of
the RGB amplifier.
“0” – fail.
“1” – successful.
Soft Power On/Off
0xc8,
“0” | “1” |
“?”
Soft power
On/off
query
“0” – soft power off.
“1” –soft power on.
Query BIOS
version
0xcb, “0”
Read BIOS version
“nnnn” = BIOS ver. “nn.nn”
Query PCBA
number
0xcb, “1”
Read PCBA number
“nnnn” = PCBA number
ALR-1920=”41727”
Load factory
defaults
0xce
Reset all parameters to factory
default value
“1” – successful.
# - Function in ARGB mode only