8
7. STATUS LED's
Power Status LED
Power LED
Action
RED
Projector in Standby
GREEN
Projector in power up cycle or projector running
YELLOW
Projector in power down cycle
Status LED's
Status LED
Steady - ON
Flashing or Off
LAMP DOOR
Lamp door closed
Lamp door open
FANS
Fans OK
Fan failure
LAMP
Lamp struck OK “ON”
Not struck / Lamp off
VIDEO SIGNAL
Valid Video Signal detected
No video or Invalid signal detected
FORMATTER
Formatters Initialised and Operating
Formatter failure - may
fl
ash during
video signal change
BALLAST TEMP
Ballast temperature OK
Ballast temperature too high
>105
˚
C
READY
Projector running/ready for power on
Cool down cycle in progress
SHUTTER
Shutter open
Shutter closed
7
Quick Power down
If the projector is in the 5 MINUTE POWER DOWN sequence, pressing the SOFT POWER switch again
(1/2 second or more) will initiate the 60 SECOND POWER OFF sequence.
To cancel 5 MINUTE POWER DOWN press the SHUTTER switch. OR If the IR remote is enabled - press
the OPEN button on the remote control which will open the SHUTTER and cancel the 5 MINUTE POWER
DOWN. The STATUS LED will turn GREEN.