7
6. POWER SEQUENCING
6
Applying power
When the power is
fi
rst applied, the projector comes up in STANDBY mode. It may be left in this state
inde
fi
nitely. Both controllers and the RS-232 circuitry are powered so that the unit can respond to serial
commands, the IR Remote Control or the rear panel switch. The ballasts, fans and formatters are not
energized.
Note: The IR Remote POWER button is always active but the other buttons may be disabled. If the unit
is powered up using the IR Remote, all IR commands will be enabled. If the unit is powered up using the
rear panel switch or via the serial port, only the IR POWER button is disable. IR Remote buttons may be
enabled or disabled with the
IR+
and
IR-
serial commands.
When the projector is in STANDBY
, the Power STATUS LED to the left of the switch will glow RED.
and the READY LED will be ON. (If there were any problems encountered, other LEDs may be
fl
ashing.)
Switching ON
Pressing the SOFT POWER switch momentarily (1/2 second or more) will power up the unit, turning on
the lamp and initializing the formatters. The Power STATUS LED will glow GREEN. The projector will
come up in CURTAIN projection mode (picture off) and with the shutter closed. The STATUS LEDs will
display the progress of the power-up sequence. When all of the LEDs except for the SHUTTER LED are
lit, then the shutter may be opened.
When the projector is POWERED UP, a momentary depression of the SHUTTER switch (1/2 second or
more) will open the SHUTTER and put the formatters in NORMAL PROJECTION MODE (picture on).
Subsequent depressions will toggle between NORMAL MODE/SHUTTER OPEN and CURTAIN MODE/
SHUTTER CLOSED.
Powering down
Pressing the SOFT POWER switch will cause the SHUTTER to close and the formatters to go to
CURTAIN MODE and also initiates a 5 MINUTE POWER DOWN cycle. During this time the lamp, fans
and formatters remain active. The Power STATUS LED will glow YELLOW. The STATUS LEDs should
all be ON except for SHUTTER. During this 5 minute cycle if no other action is taken, the projector will
enter STANDBY mode which take a further 60 seconds. During which time the lamp is turned off and the
fans are left running.
During the 60 SECOND POWER OFF sequence the READY LED will be OFF. While the READY LED
is OFF the lamp may not be turned on. The READY LED will go back ON after 90 seconds indicating
that the lamp may be re-struck. A command to re-strike via any of the three methods - serial, IR or
switch – may be issued at any time but the re-strike will not occur until the 90-second lamp cool-down
has expired.
LEDs
POWER STATUS
RED
: Standby
GREEN
: Power On or Power-up sequence
YELLOW
: 5 minute
power-down , ELSE power-off sequence.
STATUS LED Operation
STATUS LED
When on continuously
When Flashing (or OFF)
SHUTTER OPEN Shutter OPEN
Shutter CLOSED
CURTAIN mode
READY
90 Second lamp cool-down timer expired
READY for power-up or Re-strike
[READY OFF] 90 second lamp
Cool-down cycle in progress
BALLAST TEMP Ballast Temperature OK
Ballast temperature high - Shutdown
FORMATTER
Formatters Initialized and Operating
Formatter failure (usually a communication
failure ) - Shutdown
VIDEO SIGNAL
Video Signal Detected
No Video
LAMP
Lamp Struck and Operating
Lamp Extinguished
FAN
Fans OK
Fan Failure - Shutdown
LAMP DOOR
Lamp Door Interlock OK
Lamp Thermal Switch Closed
Lamp Door Open or
Lamp Thermal Switch Open-Shutdown
Features
Network connection through RJ45 connector
Allows connection of the Projector directly to the ethernet network through a RJ45 connector without
using RS232 ports on the computer and without loading any individual Projector management
software on the network server.
Network Projector management
Allows remote management of the Projector from any workstation through Internet or Intranet.
•
•
•
5.LED's and NETWORK
5
Содержание morpheus 7000hdi
Страница 11: ...11 10 DIMENSIONS 10 13 75 482 5 213 227 233 113 19 05 653 0 91 0 91 0 300 0 Dimensions in mm...