Digital Projection
M-Vision LED+IR series
WIRING DETAILS
Connection Guide
Page Conn_10
Rev D July 2014
LAN connection
TCP Port number
5450
10BaseT Unshielded Twisted Pair cable
The standard wire colours as as follows:
1
White / Orange stripe
2 Orange
3
White / Green stripe
4 Blue
5
White / Blue stripe
6 Green
7
White / Brown stripe
8 Brown
Crossed cable
(used to connect directly to a computer with no hub or network.)
(Note that only the green and orange pairs are crossed)
1
White / Orange stripe
White / Green stripe
1
2 Orange
Green
2
3
White / Green stripe
White / Orange stripe
3
4 Blue
Blue
4
5
White / Blue stripe
White / Blue stripe
5
6 Green
Orange
6
7
White / Brown stripe
White / Brown stripe
7
8 Brown
Brown
8
Notes
Only one remote connection should
be used at any one time.
For information about how to set the
LAN IP configuration, see the next
page.
Use:
a straight cable to connect to a hub
or network, or
a crossed cable as shown here
to connect ONLY to a computer
directly.
top view of cable