Digital Monitoring Products 7800 series Скачать руководство пользователя страница 19

Arming and Disarming 

Graphic Touchscreen Keypad User Guide 

15

3.   Press 

ARM

 to display 

ALL? NO  YES

Enter your user code if required.

4.   Select 

NO

 to arm only selected 

areas. Go to step 5. Select 

YES

 to 

arm all areas authorized for your 

user code.

5.   If 

NO

 is selected in step 4, 

the display begins to list 

each area to which you have access followed by 

NO  YES

Example: 

OFFICE  NO YES

.

5a. Select 

YES

 for each area you want to arm.

5b. Select 

NO

 for each area you do NOT want to arm.

Note:

 You may also press the area 

numbers you want to arm while ALL?  NO 

YES displays. This changes the display 

to AREAS:. The numbers you select 

 

appear in the display. For example: 

AREAS:  2  4. Press CMD when done.
6.  The system displays any faulted and 

bypassed zones.

7.  At this point you can 

force arm

 

or 

bypass

 any faulted burglary 

zones. A zone that is force armed 

is restored into the system if it 

later returns to normal. A zone 

that is bypassed remains bypassed 

until the system is disarmed. 

See steps 7a through 7d.

7a. If a problem exists on any zones, the zone name and problem 

are shown followed by: 

OKAY   BYPASS  STOP

.

7b. Select 

OKAY

 to force arm the 

zone(s) before arming.

7c. Select 

BYPASS

 to bypass the 

zone(s) before arming.

7d. Select 

STOP

 to stop the system 

from arming. Correct the 

zone problem(s) and return to 

step 1.

Note

: 24-hour zones cannot be bypassed. 

8.   The  screen displays 

SYSTEM ON

 if 

at least one area in the system is 

armed, and 

ALL SYSTEM ON

 if all 

areas in the system are armed.

9.   The  screen then displays the 

exit time in seconds and counts 

down the remaining time: 

ExIT: # #

 

(

# #

 = seconds remaining). When the 

entire system is armed, the keypad 

sounds the exit delay alert and 

when the delay expires, the zones 

are armed and the screen displays 

the Shield with the Area icon in 

the center.

ALL?                NO   YES

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

ALL? NO YES Keypad Display

AREAS:    1  2     4       6 

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

AREAS: Armed 

Keypad Display 

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

FRONT DOOR

  

ZONE:       1     -FAULT

  

Zone Fault Keypad Options 

OKAY

  

BYPASS STOP

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

Okay Bypass Stop 

Keypad Display 

ALL  SYSTEM  ON

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

ALL SYSTEM ON 

Keypad Display

EXIT TIMER

EXIT TIMER

MON 5:35 PM

3 5

ARM

INSTANT

Exit Timer

ARMED

Panic

Chime

Check-in

Fire Reset

TODAY

WEDNESDAY

82

CURRENT

HI     LO

98   77

HI

80

LO

74

AREA ARMED Display

Содержание 7800 series

Страница 1: ......

Страница 2: ...burglar alarm is valid press NO or VERIFY to send a verification message to the Central Station If a valid alarm has not occurred press YES or CANCEL to cancel the alarm and send an Abort or Cancel m...

Страница 3: ...Status List 9 Zone Status 9 Armed Status 9 Exit Error 9 Arming and Disarming 10 How Your System Operates 10 Arming Functions 10 Key Fob Arming 11 Key Fob Disarming 11 System Arming 12 Home Sleep Away...

Страница 4: ...Graphic Touchscreen Keypad User Guide...

Страница 5: ...ystem Graphic Touchscreen Keypad Main Screen Your system has an easy to use Graphic Touchscreen Keypad that allows you to operate the system When accessing any other screens you may return to the Main...

Страница 6: ...s an easy to understand arming options screen When leaving in a hurry press the shield until it glows the system quick arms the Away system and starts the exit timer giving you ample time to leave Onc...

Страница 7: ...d AC Power OK Battery OK Blue Blinking Panel Disarmed AC Power OK Battery Fault No Light Panel Disarmed AC Power Fault Battery OK Red Steady Panel Armed AC Power OK Battery OK Red Blue Alternate Panel...

Страница 8: ...llable options Scroll through the available options by pressing within the Carousel Menu area and moving your finger up or down You may select any options within the Carousel Menu by pressing the desi...

Страница 9: ...ECKIN Check in SENSORS OFF 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GHI 7STU 4JKL 8VWX CMD SENSORS OFF Reset EXIT TIMER EXIT TIMER MON 5 35 PM 3 5 ARM INSTANT Easy Exit SYSTEM READY 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GHI 7...

Страница 10: ...ond from the right and the fourth Select Area is the far right System Status Display System Status display shown across the top of the Main Screen displays the armed status System Ready or System Not...

Страница 11: ...Chime A tone that sounds each time a door or window is opened while you are using the Zone Monitor Chime option from the User Menu See Zone Monitor in the panel user guide Trouble A steady tone indic...

Страница 12: ...ns and if monitored send alarm reports to a Central Station when a burglary zone is faulted Fire panic and other 24 hour devices are always turned on and do not need to be armed Disarming This means t...

Страница 13: ...or battery power If your system contains any Panic zones these do not display on the screen for security reasons If an alarm occurs on a non fire 24 hour zone or a system monitor it remains in the Sta...

Страница 14: ...selected areas are arming For Home Away or Home Sleep Away systems the Keypad screen displays ALL SYSTEM ON if all areas in the system are arming HOME SYSTEM ON or SLEEP SYSTEM ON if only selected are...

Страница 15: ...ms but the interior area s remain disarmed because you have not exited Instant During the exit delay time you can cancel the exit and entry delays and cause all zones to be instant zones Press ARM INS...

Страница 16: ...east one area in the system is armed and ALL SYSTEM ON if all areas in the system are armed 6 The screen then displays the exit time in seconds and counts down the remaining time EXIT seconds remainin...

Страница 17: ...thin 5 seconds or an invalid user code is entered the prewarn tone begins sounding again 2 ALL SYSTEM OFF is displayed in the upper right corner after the system disarms the Main Screen Shield indicat...

Страница 18: ...end an alarm verify message to the Central Station The system will remain armed System Arming Area Systems Your security system is programmed into separate areas Youmayarmanddisarmallareasatonetimeore...

Страница 19: ...re arming 7d Select STOP to stop the system from arming Correct the zone problem s and return to step 1 Note 24 hourzonescannotbebypassed 8 The screen displays SYSTEM ON if at least one area in the sy...

Страница 20: ...emove an area number from the display press the corresponding number on the screen Press CMD when done 4 After all areas have displayed any alarms that occurred during the armed period are shown If al...

Страница 21: ...arming sequence is the same as Area Disarming steps 2 through 4 in the previous section 2 The screen may display ALARM CANCELLED if your system was disarmed after alarm message had been sent to the ce...

Страница 22: ...ks their status and battery status You may also LOCK or UNLOCK Z Wave equipped doors Z Wave Thermostat Screen The Z Wave Thermostat screen displays all programmed Thermostats and their status You may...

Страница 23: ...User Menu See Z Wave Setup Note The icon is only available if enabled at installation Z Wave Setup Z Wave Setup is used for managing Z Wave devices and Favorites With Z Wave Setup you can Add devices...

Страница 24: ...hose functions to which you have access are displayed Please refer to the user guide provided with your control panel for complete list and operation of the user menu Accessing the User Menu 1 Press K...

Страница 25: ...on System Trouble Yes There is a problem with one or more components in the system Contact your service person System Busy No The system is performing another task with a higher priority Wait a few mo...

Страница 26: ...Sleep Away 2 10 12 14 I Instant Zone 9 Interactive Shield 1 2 12 13 14 Interior 10 11 Invalid Code 8 K Keypad 1 3 4 6 7 8 9 11 12 13 15 20 L LED 1 3 M Main Screen 1 2 3 4 5 6 12 13 14 16 17 20 Mini Sh...

Страница 27: ...Graphic Touchscreen Keypad User Guide...

Страница 28: ...LT 1191 1 02 14315...

Отзывы: