Special Keypad Tones

Your  keypad contains an internal speaker that alerts you about 

events as they occur on your system.

Note: 

For burglary alarms, the tone will silence as soon as the first 

user code digit key is pressed. If a valid user code is not entered 

within 5 seconds or an invalid user code is entered, the burglary 

tone begins sounding again.
Below are brief descriptions of the different tones you hear from 

the keypad.

Fire alert:

 An intermittent sweeping siren that continuously repeats 

until  the  fire  alarm  is  silenced.  This  is  in  addition  to  a  separate 

siren activated by the alarm panel.

Burglary Alert:

 A siren tone that continues until the alarm is 

silenced. This is in addition to the separate siren output operated 

by the alarm panel.

Prewarn

: A tone that sounds when you open an entry delay door 

on a system that is armed (turned on) reminding you to disarm the 

burglary protection.

Your  system  will  silence  the  tone  as  soon  as  the  first 

user code 

digit key is pressed. If a valid user code is not entered within 5 

seconds or an invalid user code is entered, the prewarn tone begins 

sounding again.

Exit:

 When fully arming your system to leave, a pulsing tone sounds 

during the exit countdown just after arming to remind you to exit 

the premise. At ten seconds prior to the end of the countdown, the 

rate of pulsing increases.

Monitor (Chime):

 A tone that sounds each time a door or window is 

opened while you are using the Zone Monitor (Chime) option from 

the User Menu. See Zone Monitor in the panel user guide.

Trouble:

 A steady tone indicating a trouble condition on your 

system.

Special Keypad Displays

As you use your system, you may occasionally see a message display 

that asks you to enter a user code or describes a condition on the 

system. Below are some examples of the displays you may see.

ALARM

A 24-hour zone, such as a fire or panic zone, or an armed burglary 

zone is faulted. Keypad will sound an alarm and any other sirens 

programmed in your panel by the installer.

ALARM NOT SENT

The alarm signal was aborted and was not sent to the Central 

Station because a user code was entered to disarm the system 

before the alarm signal was sent to the Central Station. Also, your 

system may be pre-programmed at installation to send an Abort 

signal to the Central Station.

ALARM CANCELLED

An Alarm signal was sent to the Central Station and was cancelled 

by a user who entered their user code to silence the alarm.

ALARM VERIFIED

A valid burglar alarm has occurred and has been manually verified 

by the user. The alarm system also transmits a VERIFY message to 

the Central Station.

ENTER CODE

The system requires you to enter a personal user code. User codes 

can be used for turning your system on (arming), turning your 

system off (disarming), and other system options.
As you enter your user code, the display shows an asterisk (*) in 

place of each digit pressed. This prevents others from seeing your 

user code on the display as you enter it.

Содержание 7800 series

Страница 1: ......

Страница 2: ...burglar alarm is valid press NO or VERIFY to send a verification message to the Central Station If a valid alarm has not occurred press YES or CANCEL to cancel the alarm and send an Abort or Cancel m...

Страница 3: ...Status List 9 Zone Status 9 Armed Status 9 Exit Error 9 Arming and Disarming 10 How Your System Operates 10 Arming Functions 10 Key Fob Arming 11 Key Fob Disarming 11 System Arming 12 Home Sleep Away...

Страница 4: ...Graphic Touchscreen Keypad User Guide...

Страница 5: ...ystem Graphic Touchscreen Keypad Main Screen Your system has an easy to use Graphic Touchscreen Keypad that allows you to operate the system When accessing any other screens you may return to the Main...

Страница 6: ...s an easy to understand arming options screen When leaving in a hurry press the shield until it glows the system quick arms the Away system and starts the exit timer giving you ample time to leave Onc...

Страница 7: ...d AC Power OK Battery OK Blue Blinking Panel Disarmed AC Power OK Battery Fault No Light Panel Disarmed AC Power Fault Battery OK Red Steady Panel Armed AC Power OK Battery OK Red Blue Alternate Panel...

Страница 8: ...llable options Scroll through the available options by pressing within the Carousel Menu area and moving your finger up or down You may select any options within the Carousel Menu by pressing the desi...

Страница 9: ...ECKIN Check in SENSORS OFF 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GHI 7STU 4JKL 8VWX CMD SENSORS OFF Reset EXIT TIMER EXIT TIMER MON 5 35 PM 3 5 ARM INSTANT Easy Exit SYSTEM READY 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GHI 7...

Страница 10: ...ond from the right and the fourth Select Area is the far right System Status Display System Status display shown across the top of the Main Screen displays the armed status System Ready or System Not...

Страница 11: ...Chime A tone that sounds each time a door or window is opened while you are using the Zone Monitor Chime option from the User Menu See Zone Monitor in the panel user guide Trouble A steady tone indic...

Страница 12: ...ns and if monitored send alarm reports to a Central Station when a burglary zone is faulted Fire panic and other 24 hour devices are always turned on and do not need to be armed Disarming This means t...

Страница 13: ...or battery power If your system contains any Panic zones these do not display on the screen for security reasons If an alarm occurs on a non fire 24 hour zone or a system monitor it remains in the Sta...

Страница 14: ...selected areas are arming For Home Away or Home Sleep Away systems the Keypad screen displays ALL SYSTEM ON if all areas in the system are arming HOME SYSTEM ON or SLEEP SYSTEM ON if only selected are...

Страница 15: ...ms but the interior area s remain disarmed because you have not exited Instant During the exit delay time you can cancel the exit and entry delays and cause all zones to be instant zones Press ARM INS...

Страница 16: ...east one area in the system is armed and ALL SYSTEM ON if all areas in the system are armed 6 The screen then displays the exit time in seconds and counts down the remaining time EXIT seconds remainin...

Страница 17: ...thin 5 seconds or an invalid user code is entered the prewarn tone begins sounding again 2 ALL SYSTEM OFF is displayed in the upper right corner after the system disarms the Main Screen Shield indicat...

Страница 18: ...end an alarm verify message to the Central Station The system will remain armed System Arming Area Systems Your security system is programmed into separate areas Youmayarmanddisarmallareasatonetimeore...

Страница 19: ...re arming 7d Select STOP to stop the system from arming Correct the zone problem s and return to step 1 Note 24 hourzonescannotbebypassed 8 The screen displays SYSTEM ON if at least one area in the sy...

Страница 20: ...emove an area number from the display press the corresponding number on the screen Press CMD when done 4 After all areas have displayed any alarms that occurred during the armed period are shown If al...

Страница 21: ...arming sequence is the same as Area Disarming steps 2 through 4 in the previous section 2 The screen may display ALARM CANCELLED if your system was disarmed after alarm message had been sent to the ce...

Страница 22: ...ks their status and battery status You may also LOCK or UNLOCK Z Wave equipped doors Z Wave Thermostat Screen The Z Wave Thermostat screen displays all programmed Thermostats and their status You may...

Страница 23: ...User Menu See Z Wave Setup Note The icon is only available if enabled at installation Z Wave Setup Z Wave Setup is used for managing Z Wave devices and Favorites With Z Wave Setup you can Add devices...

Страница 24: ...hose functions to which you have access are displayed Please refer to the user guide provided with your control panel for complete list and operation of the user menu Accessing the User Menu 1 Press K...

Страница 25: ...on System Trouble Yes There is a problem with one or more components in the system Contact your service person System Busy No The system is performing another task with a higher priority Wait a few mo...

Страница 26: ...Sleep Away 2 10 12 14 I Instant Zone 9 Interactive Shield 1 2 12 13 14 Interior 10 11 Invalid Code 8 K Keypad 1 3 4 6 7 8 9 11 12 13 15 20 L LED 1 3 M Main Screen 1 2 3 4 5 6 12 13 14 16 17 20 Mini Sh...

Страница 27: ...Graphic Touchscreen Keypad User Guide...

Страница 28: ...LT 1191 1 02 14315...

Отзывы: