Prioris HX 6000 Server Powergrade Kit
3
Embedded - PCI VGA controller.
5. Select Save and Exit to save this selection.
Power Down the Server
1. Turn off your server.
2. Disconnect any external devices, the ac power cord, and the
monitor power cord.
3. Unlock the front security lock on the server.
4. Remove the left side panel by sliding it toward the rear of the
server.
WARNING:
You might injure yourself or damage your server if
you attempt to remove the side panel before unplugging the ac and
monitor power cords.
Remove any Video Option Cards
Before updating the BIOS, you must remove any video option card and
use the embedded PCI VGA controller.
Set Switches on the Main Logic Board
Make sure that the following switches, shown in Figure 1, are set:
SW1-1
BIOS upgrade
Enabled (On)
SW1-3
Boot block update
Enabled (On)
Replace the Panel and Reconnect the Cables
1. Install the left side panel. The server will not power up with the
side panel removed.
2. Connect the monitor video cable to the embedded VGA connector
if not already connected.