Maintenance Manual Electronic Hardware Overview
____________________________________________________________________________________________
The maximum firing frequency is 2400 Hz for alphanumeric printing and 2100 Hz
for graphic printing.
In the next figure are shown the typical waveform of the print head needle current.
The LOW and NORMAL energy can be selected via operator panel in order to
obtain the best performance in term of printout/noise when multiple forms paper is
used.
The timing values (
µ
sec) are programmed by the ASIC timer registers.
Low
Normal
T1 = Timer 1
100
115
T2 = Timer 2 typical
100
85
T3 = Timer 3
37.5
37.5
T4 = Negative duty cycle inside T3
12.5
12.5
T1+T2+discharge time
230
230
Energy (mJ)
4
5
Figure 3.15 Print Head Needle Current Waveforms
____________________________________________________________________________________________